Dimensions (W x L x H)30 x 170 x 35 mm
Type of mountingOn H-rail via accessories With through-hole
Product weight127 g
Storage temperature-40 °C ... 70 °C
Relative air humidity5 - 95% Non-condensing
Degree of protectionIP65 IP67
Note on degree of protectionUnused connections sealed
Corrosion resistance class CRC1 - Low corrosion stress
Max. cable length30 m outputs 50 m system communication
Note on max. cable lengthPower supply according to nominal voltage
LABS (PWIS) conformityVDMA24364-B2-L
Cleanroom suitability, measured according to ISO 14644-14Element installed statically, no meaningful evaluation possible according to ISO 14644-1
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC
KC markKC-EMV
ApprovalRCM trademark c UL us listed (OL)
Certificate issuing authorityUL E239998
Note on materialsRoHS-compliant
Material housingPC Die-cast zinc, nickel-plated
Material o-ringFPM
Diagnostics via LEDDiagnostics per module Load power supply Status per channel
Diagnostics per internal communicationShort-circuit/overload in output signal Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage
Number of outputs8
Communication interface, functionSystem communication XF10 IN / XF20 OUT
Communication interface, connection type2x socket
Communication interface, connection technologyM8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores4
Communication interface, protocolAP
Communication interface, screenedyes
Power supply, functionIncoming electronics/sensors and load
Power supply, connection typePlugs
power supply, connection systemM8x1, A-coded to EN 61076-2-104
Power supply, number of pins/wires4
Power transmission, functionOutgoing electronics/sensors and load
Power transmission, connection typeSocket
Power transmission, connection technologyM8x1, A-coded to EN 61076-2-104
Power transmission, number of pins/wires4
Note regarding operating voltageSELV/PELV fixed power supplies required Note voltage drop
Nominal operating voltage DC of load24 V
Permissible voltage fluctuation of load± 25 %
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Max. power supply2 x 4 A (external fuse required)
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 35 mA
Intrinsic current consumption at nominal operating voltage loadTypically 10 mA
Power failure bridging10 ms
Reverse polarity protectionyes
Electrical connection output, functionDigital output
Electrical connection output, connection type4x socket
Electrical connection output, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection output, number of connections/cores5
Characteristic for outputsAccording to IEC 61131-2, type 0.5
Switching logic for outputsPNP (positive switching)
Fuse protection of outputs (short circuit)Internal electronic fuse per channel
Output delay with ohmic loadSignal change 0->1: < 200 µs Signal change 1->0: < 200 µs
Max. residual current outputs per module4 A
Electrical isolation of outputs between channelsno
Electrical isolation of outputs between channel - internal communicationyes
Max. power supply per channel0.5 A