Dimensions (W x L x H)48.4 mm x 117.2 mm x 57.5 mm
Type of mountingOn H-rail via accessories On mounting frame Via through-hole for M5 screw Via through-hole for M6 screw
Product weight245 g
Mounting positionAny, on H-rail: horizontal
Ambient temperature-20 °C ... 50 °C
Note on ambient temperatureObserve ambient temperature derating according to IEC 61131-2:2017
Storage temperature-20 °C ... 70 °C
Relative air humidity5 - 95% Non-condensing
Nominal altitude of use<= 2000 m ASL (> 79.5 kPa)
Max. installation height3500 m
Note on max. installation heightObserve ambient temperature derating according to IEC 61131-2:2017
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Note on vibration resistanceSG1 on H-rail SG2 on direct mounting Transport application test with severity class 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Note on shock resistance30 g/11 ms to EN 60068-2-27 SG1 on H-rail SG2 on direct mounting Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection classIII
Pollution degree2
Overvoltage categoryII
Max. cable length50 m system communication
LABS (PWIS) conformityVDMA24364-B2-L
Fire test materialUL94 V-0 (housing)
Note on materialsRoHS-compliant Free of halogen Free of phosphoric acid ester
Material housingDie-cast aluminium, coated
Material coverPBT-reinforced
Material screwsNickel-plated steel Galvanised steel
Material sealsPU foam
Material o-ringFPM
Diagnostics via LEDDiagnostics per module Power supply, electronics/sensors Load power supply
Diagnostics per internal communicationCommunication fault Short circuit/overload Power OUT PL Short circuit/overload Power OUT PS Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage
Communication interface, functionSystem communication XF10 IN / XF20 OUT
Communication interface, connection type2x socket
Communication interface, connection technologyM8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores4
Communication interface, plug pattern00995937
Communication interface, protocolAP
Communication interface, screenedyes
Power transmission, functionOutgoing electronics/sensors and load
Power transmission, connection typeSocket
Power transmission, connection technologyM8x1, A-coded to EN 61076-2-104
Power transmission, number of pins/wires4
Power transmission, plug pattern00991872
Note regarding operating voltageSELV/PELV fixed power supplies required Note voltage drop
Note on nominal operating voltage DCProtected Extra-Low-Voltage to IEC 60204-1
Nominal operating voltage DC of load24 V
Permissible voltage fluctuation of load± 25 %
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 45 mA
Intrinsic current consumption at nominal operating voltage loadTypically 11 mA
Power failure bridging10 ms
Potential separation between the supply voltages electronics/sensor technology and load/valvesYes
Reverse polarity protectionyes
Behaviour after end of overload of the sensor supplyNo automatic return with overload at Power OUT
Behaviour after end of overload of the outputsNo automatic return with overload at Power OUT
Fuse protection (short circuit)Yes, Power Out PS+PL