Festo · SKU: · P/N: 8129244

CPX-AP-A-EP-M12

Be the first to review 86 sold this month 1,240 views
Dimensions (W x L x H) 50.1 mm x 107.3 mm...
Grid dimension 50.1 mm
Type of mounting Screw-clamped
Max. number of modules 80
Request Quote
Get Best Price · response within 24 hrs
QTY
Chat with Expert
Genuine OEM Festo Product

100% authentic, sourced through authorised channels

12-Month Warranty

Full replacement coverage on defects from date of dispatch

30-Day Returns Policy

Return unused items in original packaging for a full refund

Estimated Delivery Dubai, UAE — 1 business day · International — 3–5 days

Product Overview

Festo CPX-AP-A-EP-M12 — genuine OEM industrial automation spare part, supplied with a 12-month warranty and shipped worldwide from our Dubai warehouse.

Order Information

  • Stock No
  • Manufacturer P/N8129244
  • Product ID8129244
  • BrandFesto
  • CategoryValves and valve terminals

Need Help Choosing?

Our specialists can confirm compatibility, suggest accessories, and provide drop-in replacements.

Talk to a specialist

Specifications

Dimensions (W x L x H)50.1 mm x 107.3 mm x 57.5 mm
Grid dimension50.1 mm
Type of mountingScrew-clamped
Max. number of modules80
Product weight113 g
Mounting positionoptional
Ambient temperature-20 °C ... 50 °C
Note on ambient temperatureObserve ambient temperature derating according to IEC 61131-2:2017
Storage temperature-20 °C ... 70 °C
Relative air humidity5 - 95% Non-condensing
Nominal altitude of use<= 2000 m ASL (> 79.5 kPa)
Max. installation height3500 m
Note on max. installation heightObserve ambient temperature derating according to IEC 61131-2:2017
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Note on vibration resistanceSG1 on H-rail SG2 on direct mounting Transport application test with severity class 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Note on shock resistance30 g/11 ms to EN 60068-2-27 SG1 on H-rail SG2 on direct mounting Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection classIII
Pollution degree2
Overvoltage categoryII
Max. cable length100 m Ethernet/IP
LABS (PWIS) conformityVDMA24364-B2-L
Fire test materialUL94 V-0 (housing)
Note on materialsRoHS-compliant Free of halogen Free of phosphoric acid ester
Material coverPBT-reinforced
Material screenPC
Material screwsNickel-plated steel
Material threaded sleeveHigh-alloy stainless steel
Material o-ringFPM
Diagnostics via LEDDiagnostics per module Ethernet/IP communication Power supply, electronics/sensors Load power supply System diagnostics Service required
Diagnostics via busAPDD invalid Load switch-off Communication fault Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage
Fieldbus interfaceEthernet
Field bus, protocolACD (Address Conflict Detection) DLR (Device Level Ring) EtherNet/IP EtherNet/IP QoS EtherNet/IP Quickconnect Modbus/TCP (Modbus/UDP) SNMP
Fieldbus interface, functionBus connection incoming/outgoing
Field bus, connection type2x socket
Field bus, connection systemM12x1, D-coded to EN 61076-2-101
Fieldbus interface, connection pattern00995716
Field bus, connection pattern4
Field bus interface, electrical isolationyes
Field bus interface, transmission rate100 Mbit/s
Fieldbus interface, note on transmission rate100 Mbit, fast switching Ethernet
Max. address volume, inputs4096 Byte
Note on inputsEP: 488 bytes Modbus: 4096 bytes
Max. address volume, outputs4096 Byte
Note on outputsEP: 496 bytes Modbus: 4096 bytes
Module parametersConfiguration of voltage monitoring load supply PL
Internal cycle time< 1 ms
Configuration supportEDS file
Communication interface, functionSystem communication XF20 OUT
Communication interface, connection typeSocket
Communication interface, connection technologyM8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores4
Communication interface, plug pattern00995937
Communication interface, protocolAP
Communication interface, screenedyes
Note regarding operating voltageSELV/PELV fixed power supplies required Note voltage drop
Note on nominal operating voltage DCProtected Extra-Low-Voltage to IEC 60204-1
Nominal operating voltage DC of load24 V
Permissible voltage fluctuation of load± 25 %
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 95 mA
Intrinsic current consumption at nominal operating voltage loadTypically 3 mA
Power failure bridging10 ms
Potential separation between the supply voltages electronics/sensor technology and load/valvesYes
Reverse polarity protectionyes
PDF
Datasheet — CPX-AP-A-EP-M12
On request · English
PDF
CE Declaration of Conformity
On request
3D
3D / CAD Model
On request · STEP / IGES
0.0/5
No reviews yet — be the first!
5
0%
4
0%
3
0%
2
0%
1
0%
Write a Review

No reviews yet. Share your experience with this product below.

Write a Review
Your rating
Need a different rating or a related accessory?

Item added