ISO 9001:2015 Certified 12-Month Warranty Worldwide Shipping Dubai, UAE
Search using:
  • Stock number
  • Manufacturer part number
  • Keywords
Festo · SKU: · P/N: 8129243

CPX-AP-A-EC-M12

Be the first to review 86 sold this month 1,240 views
Dimensions (W x L x H) 50.1 mm x 107.3 mm...
Grid dimension 50.1 mm
Type of mounting Screw-clamped
Max. number of modules 80
Request Quote
Get Best Price · response within 24 hrs
QTY
Chat with Expert
Genuine OEM Festo Product

100% authentic, sourced through authorised channels

12-Month Warranty

Full replacement coverage on defects from date of dispatch

30-Day Returns Policy

Return unused items in original packaging for a full refund

Estimated Delivery Dubai, UAE — 1 business day · International — 3–5 days

Product Overview

Festo CPX-AP-A-EC-M12 — genuine OEM industrial automation spare part, supplied with a 12-month warranty and shipped worldwide from our Dubai warehouse.

Order Information

  • Stock No
  • Manufacturer P/N8129243
  • Product ID8129243
  • BrandFesto
  • CategoryValves and valve terminals

Need Help Choosing?

Our specialists can confirm compatibility, suggest accessories, and provide drop-in replacements.

Talk to a specialist

Specifications

Dimensions (W x L x H)50.1 mm x 107.3 mm x 57.5 mm
Grid dimension50.1 mm
Type of mountingScrew-clamped
Max. number of modules80
Product weight113 g
Mounting positionoptional
Ambient temperature-20 °C ... 50 °C
Note on ambient temperatureObserve ambient temperature derating according to IEC 61131-2:2017
Storage temperature-20 °C ... 70 °C
Relative air humidity5 - 95% Non-condensing
Nominal altitude of use<= 2000 m ASL (> 79.5 kPa)
Max. installation height3500 m
Note on max. installation heightObserve ambient temperature derating according to IEC 61131-2:2017
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Note on vibration resistanceSG1 on H-rail SG2 on direct mounting Transport application test with severity class 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Note on shock resistance30 g/11 ms to EN 60068-2-27 SG1 on H-rail SG2 on direct mounting Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection classIII
Pollution degree2
Overvoltage categoryII
Max. cable length100 m EtherCAT
LABS (PWIS) conformityVDMA24364-B2-L
Fire test materialUL94 V-0 (housing)
Note on materialsRoHS-compliant Free of halogen Free of phosphoric acid ester
Material coverPBT-reinforced
Material screenPC
Material screwsNickel-plated steel
Material threaded sleeveHigh-alloy stainless steel
Material o-ringFPM
Diagnostics via LEDDiagnostics per module EtherCAT® RUN Power supply, electronics/sensors Load power supply System diagnostics Service required
Diagnostics via busAPDD invalid Load switch-off Communication fault Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage
Fieldbus interfaceEthernet
Field bus, protocolEtherCAT® EtherCAT CoE EtherCAT Distributed Clocks (DC) EtherCAT EoE EtherCAT FoE EtherCAT Modular Device Profile (MDP)
Fieldbus interface, functionBus connection incoming/outgoing
Field bus, connection type2x socket
Field bus, connection systemM12x1, D-coded to EN 61076-2-101
Fieldbus interface, connection pattern00995716
Field bus, connection pattern4
Field bus interface, electrical isolationyes
Field bus interface, transmission rate100 Mbit/s
Fieldbus interface, note on transmission rate100 Mbit, fast switching Ethernet
Max. address volume, inputs1024 Byte
Max. address volume, outputs1024 Byte
Module parametersConfiguration of voltage monitoring load supply PL
Internal cycle time< 1 ms
Configuration supportESI file
Communication interface, functionSystem communication XF20 OUT
Communication interface, connection typeSocket
Communication interface, connection technologyM8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores4
Communication interface, plug pattern00995937
Communication interface, protocolAP
Communication interface, screenedyes
Note regarding operating voltageSELV/PELV fixed power supplies required Note voltage drop
Note on nominal operating voltage DCProtected Extra-Low-Voltage to IEC 60204-1
Nominal operating voltage DC of load24 V
Permissible voltage fluctuation of load± 25 %
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 95 mA
Intrinsic current consumption at nominal operating voltage loadTypically 3 mA
Power failure bridging10 ms
Potential separation between the supply voltages electronics/sensor technology and load/valvesYes
Reverse polarity protectionyes
PDF
Datasheet — CPX-AP-A-EC-M12
On request · English
PDF
CE Declaration of Conformity
On request
3D
3D / CAD Model
On request · STEP / IGES
0.0/5
No reviews yet — be the first!
5
0%
4
0%
3
0%
2
0%
1
0%
Write a Review

No reviews yet. Share your experience with this product below.

Write a Review
Your rating
Need a different rating or a related accessory?

Item added