Dimensions (W x L x H)50.1 mm x 107.3 mm x 57.5 mm
Grid dimension50.1 mm
Type of mountingScrew-clamped
Product weight93 g
Mounting positionoptional
Ambient temperature-20 °C ... 50 °C
Note on ambient temperatureObserve ambient temperature derating according to IEC 61131-2:2017
Storage temperature-20 °C ... 70 °C
Relative air humidity5 - 95% Non-condensing
Nominal altitude of use<= 2000 m ASL (> 79.5 kPa)
Max. installation height3500 m
Note on max. installation heightObserve ambient temperature derating according to IEC 61131-2:2017
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Note on vibration resistanceSG1 on H-rail SG2 on direct mounting Transport application test with severity class 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Note on shock resistance30 g/11 ms to EN 60068-2-27 SG1 on H-rail SG2 on direct mounting Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection classIII
Pollution degree2
Overvoltage categoryII
Max. cable length30 m inputs
LABS (PWIS) conformityVDMA24364-B2-L
Fire test materialUL94 V-0 (housing)
Note on materialsRoHS-compliant Free of halogen Free of phosphoric acid ester
Material coverPBT-reinforced
Material screwsNickel-plated steel
Material o-ringFPM
Diagnostics via LEDDiagnostics per module Status per channel
Diagnostics per internal communicationCommunication fault Short circuit/overload in sensor supply Electronics/sensors overvoltage Electronics/sensors undervoltage
Max. address volume, inputs1 Byte
Channel parametersInput debounce time
Communication interface, protocolAP
Note regarding operating voltageSELV/PELV fixed power supplies required Note voltage drop
Note on nominal operating voltage DCProtected Extra-Low-Voltage to IEC 60204-1
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 40 mA
Power failure bridging10 ms
Reverse polarity protectionyes
Electrical connection input, functionDigital input
Electrical connection input, connection type8x terminal strip
Electrical connection input, connector systemSpring-loaded terminal
Electrical connection input, connection pattern00997388
Electrical connection for input, conductor cross section0.25 mm² ... 1.5 mm²
Electrical connection for input, note on conductor cross section0.25-1.5 flex.w.wire end.,rigid 0.13-1.5 flex. without wire ferrule
Electrical connection for input, AWG conductor cross sectionAWG24 - AWG16
Number of inputs8
Characteristic for inputsTo IEC 61131-2, type 3
Switching levelSignal 0: <= 5 V Signal 1: >= 11 V
Switching logic for inputsPNP (positive switching) 2-wire sensors to IEC 61131-2 3-wire sensors to IEC 61131-2
Input debounce time3 ms (standard) 10 ms 20 ms
Behaviour after end of overload of the sensor supplyAutomatic return
Fuse protection of inputs (short circuit)Internal electronic fuse per module
Max. residual current of inputs per module1.8 A
Electrical isolation of inputs between channelsno
Electrical isolation of inputs between channel – internal communicationyes
Max. power supply per channel0.5 A