ProtocolEtherNet/IP Modbus® TCP
Dimensions (W x L x H)40 x 91 x 50 mm
Product weight98 g
Ambient temperature0 °C ... 50 °C
Storage temperature-20 °C ... 70 °C
Degree of protectionIP65 IP67
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364 zone III
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
ApprovalRCM trademark c UL us listed (OL)
Explosion protectionClass I, Div. 2 (CA) Class I, Div. 2 (US) Class II, Div. 2 (CA) Class II, Div. 2 (US) Zone 0 (BR) Zone 2 (ATEX) Zone 2 (CA) Zone 2 (CN) Zone 2 (IEC-EX) Zone 2 (KR) Zone 2 (UKEX) Zone 2 (US) Zone 22 (ATEX) Zone 22 (BR) Zone 22 (CA) Zone 22 (CN) Zone 22 (IE
ATEX category gasII 3G
ATEX category dustII 3D
Explosion protection certification outside the EUClass I, Div. 2 (CA) Class I, Div. 2 (US) Class II, Division 2 (CA) Class II, Div. 2 (US) Class III (CA) Class III (US) EPL Dc (BR) EPL Dc (CA) EPL Dc (CN) EPL Dc (GB) EPL Dc (IECEx) EPL Dc (KR) EPL Dc (US) EPL Ga (BR) EPL Gc (CA) EPL Gc (CN) EPL Gc (GB)
Explosion ignition protection type for gasEx ec IIC Gc X
Explosion ignition protection type for dustEx tc IIIC Dc X
Explosion ambient temperature-5°C <= Ta <= +50°C
Certificate issuing authorityDNV 23.0350 X/00 IECEx IBE 17.0003 X KTL 24-KA4BO-0392X KTL 24-KA4BO-0393X KTL 24-KA4BO-0394X KTL 24-KA4BO-0395X NEPSI GYJ19.1188X SITIIAS CCC 202032230700686 UL E239998
Note on materialsRoHS-compliant
Material housingPA
LED display, product-specificPS: Operating voltage for electronics and load supply X1: System status of module at I-Port 1 X2: System status of module at I-Port 2
LED display, bus-specificNS: Network status TP1: Network active port 1 TP2: Network active port 2
DiagnosisCommunication fault System diagnostics Undervoltage
Operator controlsDIL switch
Field bus interface2x socket, M12x1, 4-pin, D-coded
Max. address volume, inputs64 Byte
Max. address volume, outputs64 Byte
ParameterisationDiagnostic behaviour Fail-safe and idle response
Baud rate10/100 Mbit/s
Internal cycle time1 ms per 1 byte of user data
Configuration supportEDS file
Additional functionsIP addressing via DHCP, DIL switch, fieldbus or FFT Integrated switch Ring topology (DLR) SNMP Start-up parameterisation in plain text via fieldbus System status can be mapped using process data Web servers
Operational voltage range DC18 V ... 30 V
Nominal operating voltage DC24 V
Max. power supply4 A
Intern power consumption nominal operating voltageTyp. 65 mA