ProtocolPROFINET
Dimensions (W x L x H)40 x 91 x 50 mm
Grid dimension40 mm
Type of mountingOn electrical interface On electrical sub-base
Product weight93 g
Storage temperature-20 °C ... 70 °C
Degree of protectionIP65 IP67
Note on degree of protectionIn assembled state Unused connections sealed
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364 zone III
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
ApprovalRCM trademark c UL us listed (OL)
Explosion protectionClass I, Div. 2 (CA) Class I, Div. 2 (US) Class II, Div. 2 (CA) Class II, Div. 2 (US) Zone 0 (BR) Zone 2 (ATEX) Zone 2 (CA) Zone 2 (CN) Zone 2 (IEC-EX) Zone 2 (KR) Zone 2 (UKEX) Zone 2 (US) Zone 22 (ATEX) Zone 22 (BR) Zone 22 (CA) Zone 22 (CN) Zone 22 (IE
ATEX category gasII 3G
ATEX category dustII 3D
Explosion protection certification outside the EUClass I, Div. 2 (CA) Class I, Div. 2 (US) Class II, Division 2 (CA) Class II, Div. 2 (US) Class III (CA) Class III (US) EPL Dc (BR) EPL Dc (CA) EPL Dc (CN) EPL Dc (GB) EPL Dc (IECEx) EPL Dc (KR) EPL Dc (US) EPL Ga (BR) EPL Gc (CA) EPL Gc (CN) EPL Gc (GB)
Explosion ignition protection type for gasEx ec IIC Gc X
Explosion ignition protection type for dustEx tc IIIC Dc X
Explosion ambient temperature-5°C <= Ta <= +50°C
Certificate issuing authorityDNV 23.0350 X/00 IECEx IBE 17.0003 X KTL 24-KA4BO-0392X KTL 24-KA4BO-0393X KTL 24-KA4BO-0394X KTL 24-KA4BO-0395X NEPSI GYJ19.1188X SITIIAS CCC 202032230700686 UL E239998
Note on materialsRoHS-compliant
Material housingPA
LED display, product-specificPS: Operating voltage for electronics and load supply X1: System status of module at I-Port 1 X2: System status of module at I-Port 2
LED display, bus-specificNF: Network fault TP1: Network active port 1 TP2: Network active port 2
DiagnosisCommunication fault System diagnostics Undervoltage
Fieldbus interfaceEthernet
Field bus, protocolPROFINET RT
Fieldbus interface, functionBus connection incoming/outgoing
Field bus, connection type2x socket
Field bus, connection systemM12x1, D-coded to EN 61076-2-101
Fieldbus interface, connection pattern00995716
Field bus, connection pattern4
Field bus interface, electrical isolationyes
Field bus interface, transmission rate100 Mbit/s
Max. address volume, inputs64 Byte
Max. address volume, outputs64 Byte
Internal cycle time1 ms per 1 byte of user data
Configuration supportGSDML file
Additional functionsLLDP MRP PROFINET IRT PROFIenergy SNMP Shared device Web servers
Power supply, functionElectronics and load
Power supply, connection typePlugs
power supply, connection systemM12x1, A-coded according to EN 61076-2-101
Power supply, connection pattern00995383
Power supply, number of pins/wires5
Operational voltage range DC18 V ... 30 V
Nominal operating voltage DC24 V
Max. power supply4 A
Intern power consumption nominal operating voltageTyp. 80 mA