ISO 9001:2015 Certified 12-Month Warranty Worldwide Shipping Dubai, UAE
Search using:
  • Stock number
  • Manufacturer part number
  • Keywords
Festo · SKU: · P/N: 8086606

CPX-AP-I-4AI-U-I-RTD-M12

Be the first to review 86 sold this month 1,240 views
Dimensions (W x L x H) 30 x 170 x 35 mm
Type of mounting On H-rail via acce...
Product weight 166 g
Storage temperature -40 °C ... 70 °C
Request Quote
Get Best Price · response within 24 hrs
QTY
Chat with Expert
Genuine OEM Festo Product

100% authentic, sourced through authorised channels

12-Month Warranty

Full replacement coverage on defects from date of dispatch

30-Day Returns Policy

Return unused items in original packaging for a full refund

Estimated Delivery Dubai, UAE — 1 business day · International — 3–5 days

Product Overview

Festo CPX-AP-I-4AI-U-I-RTD-M12 — genuine OEM industrial automation spare part, supplied with a 12-month warranty and shipped worldwide from our Dubai warehouse.

Order Information

  • Stock No
  • Manufacturer P/N8086606
  • Product ID8086606
  • BrandFesto
  • CategoryValves and valve terminals

Need Help Choosing?

Our specialists can confirm compatibility, suggest accessories, and provide drop-in replacements.

Talk to a specialist

Specifications

Dimensions (W x L x H)30 x 170 x 35 mm
Type of mountingOn H-rail via accessories With through-hole
Product weight166 g
Storage temperature-40 °C ... 70 °C
Relative air humidity5 - 95% Non-condensing
Degree of protectionIP65 IP67
Note on degree of protectionUnused connections sealed
Corrosion resistance class CRC1 - Low corrosion stress
Max. cable length30 m inputs 50 m system communication
LABS (PWIS) conformityVDMA24364-B2-L
Cleanroom suitability, measured according to ISO 14644-14Element installed statically, no meaningful evaluation possible according to ISO 14644-1
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC
KC markKC-EMV
ApprovalRCM trademark c UL us listed (OL)
Certificate issuing authorityUL E239998
Note on materialsRoHS-compliant
Material housingPC Die-cast zinc, nickel-plated
Material sealsNBR
Material o-ringFPM
Diagnostics via LEDDiagnostics per module Status per channel
Diagnostics per internal communicationWire break Module error Short circuit/overload in sensor supply Parameter errors Parameterisation error Overload at analogue inputs Upper limit value violated Overflow/underflow Lower limit value not observed
Communication interface, functionSystem communication XF10 IN / XF20 OUT
Communication interface, connection type2x socket
Communication interface, connection technologyM8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores4
Communication interface, protocolAP
Communication interface, screenedyes
Power supply, functionIncoming electronics/sensors and load
Power supply, connection typePlugs
power supply, connection systemM8x1, A-coded to EN 61076-2-104
Power supply, number of pins/wires4
Power transmission, functionOutgoing electronics/sensors and load
Power transmission, connection typeSocket
Power transmission, connection technologyM8x1, A-coded to EN 61076-2-104
Power transmission, number of pins/wires4
Note regarding operating voltageSELV/PELV fixed power supplies required Note voltage drop
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Max. power supply2 x 4 A (external fuse required)
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 38 mA
Power failure bridging10 ms
Reverse polarity protectionyes
Electrical connection input, functionAnalogue input
Electrical connection input, connection type4x socket
Electrical connection input, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection input, note on connector systemTo achieve compliance with the technical specifications, the opposite side must be screened and designed with gold contact surfaces.
Electrical connection input, number of connections/cores5
Number of inputs4
Fuse protection of inputs (short circuit)Internal electronic fuse per module
Max. residual current of inputs per module1 A
Electrical isolation of inputs between channelsno
Electrical isolation of inputs between channel – internal communicationyes
Measured variableVoltage Current Temperature Resistor
Note on the measured variableTemperature: PT100 and NI100 supported
Data format15 bits + prefix Linear scaling
analog input-10 - 10 V -5 - 5 V 0 - 10 V 1 - 5 V 0 - 20 mA 4 - 20 mA 0 - 500 Ohm
Repetition accuracy±0.025% at 25°C
Basic error limit at 25 °C±0.1% for voltage ±0.1% for current ±0.4% for temperature ±0.2% for resistor
Operating error limit related to the ambient temperature range±0.15% for voltage ±0.15% for current ±0.9% for temperature ±0.35% for resistor
PDF
Datasheet — CPX-AP-I-4AI-U-I-RTD-M12
On request · English
PDF
CE Declaration of Conformity
On request
3D
3D / CAD Model
On request · STEP / IGES
0.0/5
No reviews yet — be the first!
5
0%
4
0%
3
0%
2
0%
1
0%
Write a Review

No reviews yet. Share your experience with this product below.

Write a Review
Your rating
Need a different rating or a related accessory?

Item added