ProtocolIO-Link®
Dimensions (W x L x H)30 x 170 x 35 mm
Type of mountingOn H-rail via accessories With through-hole
Product weight126 g
Storage temperature-40 °C ... 70 °C
Relative air humidity5 - 95% Non-condensing
Degree of protectionIP65 IP67
Note on degree of protectionUnused connections sealed
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Pollution degree2
Overvoltage categoryII
Max. cable length50 m system communication
LABS (PWIS) conformityVDMA24364-B2-L
Cleanroom suitability, measured according to ISO 14644-14Element installed statically, no meaningful evaluation possible according to ISO 14644-1
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC To UK RoHS instructions
KC markKC-EMV
ApprovalRCM trademark c UL us listed (OL)
Certificate issuing authorityUL E239998
Note on materialsRoHS-compliant
Material housingPC Die-cast zinc, nickel-plated
Material o-ringFPM
Diagnostics via LEDDiagnostics per channel Diagnostics per module Load power supply Status per channel Status per module
Diagnostics per internal communicationIO-Link® event Short circuit/overload in sensor supply Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage
Communication interface, functionSystem communication XF10 IN / XF20 OUT
Communication interface, connection type2x socket
Communication interface, connection technologyM8x1, D-coded according to EN 61076-2-114
Communication interface, number of pins/cores4
Communication interface, protocolAP
Communication interface, screenedyes
Power supply, functionIncoming electronics/sensors and load
Power supply, connection typePlugs
power supply, connection systemM8x1, A-coded to EN 61076-2-104
Power supply, number of pins/wires4
Power transmission, functionOutgoing electronics/sensors and load
Power transmission, connection typeSocket
Power transmission, connection technologyM8x1, A-coded to EN 61076-2-104
Power transmission, number of pins/wires4
Note regarding operating voltageSELV/PELV fixed power supplies required Note voltage drop
Nominal operating voltage DC of load24 V
Permissible voltage fluctuation of load± 25 %
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Max. power supply2 x 4 A (external fuse required)
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 55 mA
Intrinsic current consumption at nominal operating voltage loadTypically 5 mA
Power failure bridging10 ms
Reverse polarity protectionyes
Max. residual current of inputs per module2 A
Max. residual current outputs per module4 A
Electrical connection for IO-Link, connection type4 x socket
Electrical connection for IO-Link, connection technologyM12x1, A-coded to EN 61076-2-101
Electrical connection for IO-Link, number of pins/wires5
IO-Link, communicationC/Q green LED
IO-Link, Number of ports4
IO-Link, Port classB
IO-Link, Protocol versionMaster V 1.1
IO-Link, communication modeDI, COM1. COM2. COM3. Configurable via software
IO-Link, Process data length OUTCan be parameterised, 8-128 bytes
IO-Link, Process data length INCan be parameterised, 12-132 bytes
IO-Link, Min. cycle timeDependent on minimum supported cycle time of the connected IO-Link® device