ISO 9001:2015 Certified 12-Month Warranty Worldwide Shipping Dubai, UAE
Search using:
  • Stock number
  • Manufacturer part number
  • Keywords
Festo · SKU: · P/N: 8079933

CPX-AP-A

Be the first to review 86 sold this month 1,240 views
Electrical control AP interface Ether...
Protocol AP
Dimensions (W x L x H) Depending on confi...
Grid dimension 50.1 mm
Request Quote
Get Best Price · response within 24 hrs
QTY
Chat with Expert
Genuine OEM Festo Product

100% authentic, sourced through authorised channels

12-Month Warranty

Full replacement coverage on defects from date of dispatch

30-Day Returns Policy

Return unused items in original packaging for a full refund

Estimated Delivery Dubai, UAE — 1 business day · International — 3–5 days
Trusted by Leading Brands

Product Overview

Festo CPX-AP-A — genuine OEM industrial automation spare part, supplied with a 12-month warranty and shipped worldwide from our Dubai warehouse.

Order Information

  • Stock No
  • Manufacturer P/N8079933
  • Product ID8079933
  • BrandFesto
  • CategoryValves and valve terminals

Need Help Choosing?

Our specialists can confirm compatibility, suggest accessories, and provide drop-in replacements.

Talk to a specialist

Specifications

Electrical controlAP interface Ethernet
ProtocolAP
Dimensions (W x L x H)Depending on configuration
Grid dimension50.1 mm
Type of mountingOn H-rail via accessories On mounting frame Screw-clamped With through-hole for M5 screw with accessories With through-hole for M6 screw with accessories Via through-hole for M5 screw Via through-hole for M6 screw
Max. number of modules15
Product weight450 g ... 5200 g
Mounting positionAny, on H-rail: horizontal
Note on ambient temperatureObserve derating according to user documentation Observe ambient temperature derating according to IEC 61131-2:2017
Storage temperature-20 °C ... 70 °C
Relative air humidity5 - 95% Non-condensing
Nominal altitude of use<= 2000 m ASL (> 79.5 kPa)
Max. installation height3500 m
Note on max. installation heightObserve derating according to user documentation Observe ambient temperature derating according to IEC 61131-2:2017
Degree of protectionIP65 IP67
Note on degree of protectionUnused connections sealed
Corrosion resistance class CRC1 - Low corrosion stress
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Note on vibration resistanceSG1 on H-rail SG2 on direct mounting Transport application test with severity class 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Note on shock resistance30 g/11 ms to EN 60068-2-27 SG1 on H-rail SG2 on direct mounting Shock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection classIII
Protection against direct and indirect contactSELV/PELV power supply units required
Pollution degree2
Overvoltage categoryII
LABS (PWIS) conformityVDMA24364-B2-L
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
KC markKC-EMV
ApprovalRCM trademark c UL us listed (OL)
Certificate issuing authorityUL E239998
Note on materialsRoHS-compliant Free of halogen Free of phosphoric acid ester
Diagnostics via LEDDiagnostics per channel Diagnostics per module EtherCAT® RUN Ethernet/IP communication PROFINET communication Power supply, electronics/sensors Load power supply Status per channel Status per module System diagnostics Service required
Diagnostics via busAPDD invalid Load switch-off Communication fault Electronics/sensors overvoltage Load overvoltage Electronics/sensors undervoltage Load undervoltage
Diagnostics per internal communicationWire break IO-Link® event Communication fault Short-circuit/overload in output signal Short circuit/overload Power OUT PL Short circuit/overload Power OUT PS Short circuit/overload in sensor supply Short circuit/overload Parameter errors Parameterisation
Note on fieldbus interfaceAll information that is relevant to CPX-AP can be read out via the Ethernet interfaces/fieldbus connections and changed depending on the function. Auto MDI, the bus module performs a crossover check Firmware update via Ethernet interface/fieldbus interfac
Fieldbus interfaceEthernet
Field bus, protocolACD (Address Conflict Detection) DLR (Device Level Ring) EtherCAT® EtherCAT CoE EtherCAT Distributed Clocks (DC) EtherCAT EoE EtherCAT FoE EtherCAT Modular Device Profile (MDP) EtherNet/IP EtherNet/IP QoS EtherNet/IP Quickconnect LLDP MRP, MRPD (ring redu
Fieldbus interface, functionBus connection incoming/outgoing
Field bus, connection type2x socket
Field bus, connection systemM12x1, D-coded to EN 61076-2-101 RJ45 to IEC 61076-3-117 (V14) SCRJ to IEC 61754-24-21
Field bus, connection pattern2 ... 8
Field bus interface, electrical isolationyes
Field bus interface, transmission rate100 Mbit/s
Max. address volume, inputs1024 Byte
Note on inputsEP: 488 bytes Modbus: 4096 bytes
Max. address volume, outputs1024 Byte
Note on outputsEP: 496 bytes Modbus: 4096 bytes
Module parametersFDevice destination address FDevice source address Configuration of voltage monitoring load supply PL Behaviour after short circuit/overload at the output
Channel parametersActivation diagnostics for IO-Link® device lost Input debounce time Measured value smoothing Port mode Signal range Target deviceID Target vendorID Target cycle time Lower/upper limits Activation of linear scaling Unit for temperature measurement Hysteres
Internal cycle time< 1 ms
Configuration supportEDS file ESI file GSDML file IODD file
Power supply, functionIncoming electronics/sensors and load and functional earth Incoming electronics/sensors and load
Power supply, connection typePlugs
power supply, connection system7/8“ to NFPA/T3.5.29 M12x1, L-coded to EN 61076-2-111 M18x1 M8x1, A-coded to EN 61076-2-104 Push-pull to IEC 61076-3-126
Power supply, number of pins/wires4 ... 5
Note regarding operating voltageSELV/PELV fixed power supplies required Note voltage drop
Note on nominal operating voltage DCProtected Extra-Low-Voltage to IEC 60204-1
Nominal operating voltage DC of load24 V
Permissible voltage fluctuation of load± 25 %
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Max. power supply4 A ... 16 A
Typ. intrinsic current consumption at nominal operating voltage for electronic system/sensors40 mA ... 10000 mA
Typ. intrinsic current consumption at nominal operating voltage, load3 mA ... 10000 mA
Power failure bridging10 ms
Potential separation between the supply voltages electronics/sensor technology and load/valvesYes
Reverse polarity protectionyes
PDF
Datasheet — CPX-AP-A
On request · English
PDF
CE Declaration of Conformity
On request
3D
3D / CAD Model
On request · STEP / IGES
0.0/5
No reviews yet — be the first!
5
0%
4
0%
3
0%
2
0%
1
0%
Write a Review

No reviews yet. Share your experience with this product below.

Write a Review
Your rating
Need a different rating or a related accessory?

Item added