Electrical controlFieldbus I-Port IO-Link® Multi-pin plug
Electrical I/O systemno
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Media temperature-5 °C ... 60 °C
Storage temperature-10 °C ... 60 °C
Degree of protectionIP20 IP65
Corrosion resistance class CRC2 - Moderate corrosion stress
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Operating pressure-0.9 bar ... 10 bar
Pilot pressure1.5 bar ... 8 bar
Operating pressure for valve terminal with internal pilot air supply1.5 bar ... 8 bar
LABS (PWIS) conformityVDMA24364-B2-L
CE mark (see declaration of conformity)To EU EMC Directive To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
ApprovalRCM trademark c UL us - Recognized (OL)
Explosion protectionZone 2 (ATEX) Zone 2 (BR) Zone 22 (ATEX) Zone 22 (BR)
ATEX category gasII 3G
ATEX category dustII 3D
Explosion protection certification outside the EUEPL Dc (BR) EPL Gc (BR)
Explosion ignition protection type for gasClass I, Zone 2, AEx ec IIC Gc (US) Ex ec IIC Gc (CA) Ex ec IIC T4 Gc
Explosion ignition protection type for dustClass II, Zone 22, AEx tc IIIC T135 Dc (US) Ex tc IIIC T135 Dc (CA) Ex tc IIIC T135°C Dc
Explosion ambient temperature-5°C <= Ta <= +50°C -5°C <= Ta <= +60°C
Certificate issuing authority24-KA4BO-0392X 24-KA4BO-0393X 24-KA4BO-0394X 24-KA4BO-0395X DNV 23.0350 X/00 IBExU16ATEXB021 X IECEx IBE 17.0003 X IECEx IBE 19.0018 X UL E198674 UL MH19482
Note on materialsRoHS-compliant
Material sealsHNBR NBR
Valve terminal structureFixed grid
Max. number of valve positions24
Max. number of pressure zones13
Type of actuationElectric
Valve function2x3/2-way, monostable, closed 2x3/2-way, open, monostable 2x3/2-way, open/closed, monostable 3/2-way, closed, monostable 3/2 open, monostable 5/2 bistable 5/2-way, monostable 5/3-way, pressurised 5/3 exhausted 5/3 closed
DesignPiston gate valve
Sealing principleSoft
Type of pilotingPilot actuated
Valve size18 mm
Pilot air supplyExternal Internal
Max. standard nominal flow rate330 l/min at 10 mm 630 l/min at 14 mm 1200 l/min at 18 mm
Standard nominal flow rate (standardised to DIN 1343)130 l/min ... 1150 l/min
Suitability for vacuumyes
Exhaust-air functionWith flow control option
pneumatic working portM5 M7 G1/8 G1/4 QS-3 QS-4 QS-6 QS-8 QS-10 QS-5/32 QS-1/8 QS-3/16 QS-1/4 QS-5/16 QS-3/8
Pneumatic connection, port 1QS-16 QS-1/4 QS-5/16 QS-3/8 QS-1/2
Pilot air port 12/14G1/8
Signal status displayLED
Nominal operating voltage DC24 V
Permissible voltage fluctuations+/- 10 % +/- 25%
Nominal pick-up current per solenoid coil47 mA up to 20 ms
Nominal current with current reduction15.5 mA after 20 ms