ProtocolCANopen
Dimensions (W x L x H)40 x 91 x 50 mm
Grid dimension40 mm
Type of mountingOn electrical interface On electrical sub-base
Product weight90 g
Ambient temperature0 °C ... 50 °C
Storage temperature-20 °C ... 70 °C
Degree of protectionIP65 IP67
Note on degree of protectionIn assembled state Unused connections sealed
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364 zone III
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
KC markKC-EMV
ApprovalRCM trademark c UL us listed (OL)
Note on materialsRoHS-compliant
Material housingPA
LED display, product-specificPS: Operating voltage for electronics and load supply X1: System status of module at I-Port 1 X2: System status of module at I-Port 2
LED display, bus-specificIO: I/O status MNS: Network status
DiagnosisCommunication fault System diagnostics Undervoltage
Operator controlsDIL switch
Note on fieldbus interfaceOptional connection technology with accessories: micro style (plug/socket M12x1 A-coded, 5-pin, IP65 protection), open style (terminal strip, 5-pin, IP20 protection) Open style (screw terminal, 5-pin, IP20 protection) Optional connection technology with a
Fieldbus interfaceCAN bus
Field bus, protocolCANopen
Fieldbus interface, functionBus connection incoming/outgoing
Field bus, connection typePlugs
Field bus, connection systemSub-D
Fieldbus interface, connection pattern00995639
Field bus, connection pattern9
Field bus interface, electrical isolationyes
Field bus interface, transmission rate1000 kbit/s 125 kbit/s 250 kbit/s 500 kbit/s
Max. address volume, inputs8 Byte
Note on inputsExpandable to max. 16 bytes
Max. address volume, outputs8 Byte
Note on outputsExpandable to max. 16 bytes
ParameterisationDiagnostic behaviour Fail-safe response
Internal cycle time1 ms per 1 byte of user data
Configuration supportEDS file
Additional functionsAcyclic data access via SDO Emergency message
Power supply, functionElectronics and load
Power supply, connection typePlugs
power supply, connection systemM12x1, B-encoded to EN 61076-2-101
Power supply, connection pattern00995719
Power supply, number of pins/wires5
Operational voltage range DC18 V ... 30 V
Nominal operating voltage DC24 V
Max. power supply4 A
Intern power consumption nominal operating voltageTyp. 65 mA