Electrical controlFieldbus
Electrical I/O systemyes
Terminal type44
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Ambient temperature-5 °C ... 50 °C
Storage temperature-20 °C ... 60 °C
Relative air humidity0 - 90%
Degree of protectionIP65
Corrosion resistance class CRC0 - No corrosion stress
Operating pressure-0.9 bar ... 10 bar
Pilot pressure3 bar ... 10 bar
Operating pressure for valve terminal with internal pilot air supply43.5 psi ... 145 psi
CE mark (see declaration of conformity)To EU EMC Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
KC markKC-EMV
ApprovalBIA C-Tick c UL us - Recognized (OL)
Note on materialsRoHS-compliant
Valve terminal structureModular, valve sizes can be mixed
Type of actuationElectric
Valve function5/3-way, port 2 pressurised, 4 exhausted
DesignPiston gate valve
Valve size18 mm
Pilot air supplyExternal Internal
Max. standard nominal flow rate550 l/min at 18 mm 1100 l/min at 26 mm 1300 l/min at 42 mm 2900 l/min at 52 mm 4000 l/min at 65 mm
Suitability for vacuumyes
Exhaust-air functionVia throttle plate
pneumatic working port1/8 NPTF 1/4 NPT 3/8 NPT 1/2 NPT 1 1/2 NPT QS-6 QS-8 QS-10 QS-12 QS-16
Signal status displayLED
Nominal operating voltage DC24 V
Permissible voltage fluctuations+/- 10 %