Electrical controlIndividual connection
Terminal type16
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Media temperature-5 °C ... 50 °C
Storage temperature-20 °C ... 60 °C
Relative air humidity0 - 90%
Degree of protectionIP65 NEMA 4
Corrosion resistance class CRC0 - No corrosion stress
Operating pressure-0.9 bar ... 16 bar
Pilot pressure3 bar ... 10 bar
LABS (PWIS) conformityVDMA24364-B2-L
Note on materialsRoHS-compliant
Material sealsHNBR NBR
Valve terminal structureModular, valve sizes can be mixed
Max. number of valve positions16
Max. number of pressure zones3
Type of actuationElectric
Valve function2x3/2-way, monostable, closed 2x3/2-way, open, monostable 2x3/2-way, open/closed, monostable 5/2 bistable 5/2-way, bistable, dominant 5/2-way, monostable 5/3-way, pressurised 5/3 exhausted 5/3 closed
DesignPiston gate valve
Valve size26 mm
Max. standard nominal flow rate550 l/min at 18 mm 1100 l/min at 26 mm
Width18 mm 26 mm
Suitability for vacuumyes
Exhaust-air functionVia throttle plate
pneumatic working portG1/8 G1/4 G3/8 G1/2 QS-8 QS-10 QS-12 QS-16
Permissible voltage fluctuations-15%/+10%