ProtocolCC-Link
Dimensions (W x L x H)50 x 107 x 50 mm
Product weight115 g
Storage temperature-20 °C ... 70 °C
Degree of protectionIP65 IP67
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L
Material housingPC
LED display, product-specificM: Modify, parameterisation PL: Load supply PS: Electronics supply, sensor supply SF: System fault
LED display, bus-specificError: Communication error RD: Receive data Run: Communication status SD: Send data
Device-specific diagnosticsChannel-oriented and module-oriented diagnostics Undervoltage of modules Diagnostic memory
Operator controlsDIL switch
Field bus interfaceSub-D socket, 9-pin Sub-D plug connector, for self-assembly Screw terminal strip, IP20
Max. address volume, inputs32 Byte
Note on inputs14 bytes on Rx (F23) 32 bytes on RWr (F23) 64 bytes on Rx, RWr (F24)
Max. address volume, outputs32 Byte
Note on outputs14 bytes with Ry (F23) 32 bytes with RWw (F23) 64 bytes on Ry, RWw (F24)
ParameterisationDiagnostic behaviour Fail-safe response Forcing of channels Signal setup System parameter
Baud rate156 ... 10000 kbit/s
Additional functionsSystem status can be mapped using process data Additional diagnostic interface for operator units
Operational voltage range DC18 V ... 30 V
Nominal operating voltage DC24 V
Intern power consumption nominal operating voltageTyp. 70 mA