Dimensions (W x L x H)75.9 mm x 82.5 mm x 124.3 mm
Grid dimension18.9 mm
Type of mountingWith H-rail
Max. number of modules10
Product weight288 g
Mounting positionVertical Horizontal
Note on ambient temperature-5 - 60°C for vertical installation
Storage temperature-20 °C ... 70 °C
Relative air humidity95 % Non-condensing
Degree of protectionIP20
Corrosion resistance class CRC0 - No corrosion stress
Vibration resistanceTransport application test with severity level 1 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 1 to FN 942017-5 and EN 60068-2-27
Protection against direct and indirect contactPELV
LABS (PWIS) conformityVDMA24364 zone III
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
KC markKC-EMV
ApprovalRCM trademark c UL us listed (OL)
Certificate issuing authorityUL E239998
Note on materialsRoHS-compliant
Material housingPA
Diagnostics via LEDForce mode Module status Network fault Network status, engineering port 1 Network status, engineering port 2 EtherCAT® network status Network status, port 1 Network status, port 2 Run Power supply, electronics/sensors Load power supply System fault Servic
Operator controlsDIL switch for RUN/STOP Optional: CDSB operator unit
IP address settingDHCP Via CODESYS Optional: via operator unit CDSB
Fieldbus interfaceEthernet
Field bus, protocolLLDP MRP, MRPD (ring redundancy) PROFINET I&M0 .. 3 PROFINET IO PROFINET RT PROFINET shared device SNMP
Fieldbus interface, functionBus connection incoming/outgoing
Field bus, connection type2x socket
Field bus, connection systemRJ45
Fieldbus interface, connection pattern00995789
Field bus, connection pattern8
Field bus interface, electrical isolationyes
Field bus interface, transmission rate100 Mbit/s
Fieldbus interface 2, typeEthernet
Fieldbus interface 2, protocolCoE EoE EtherCAT® EtherCAT master FoE
Fieldbus interface 2, functionOutgoing bus connection
Fieldbus interface 2, connection typeSocket
Fieldbus interface 2, connection technologyRJ45
Fieldbus interface 2, connection pattern00995789
Fieldbus interface 2, number of pins/wires8
Fieldbus interface 2, galvanic isolationyes
Fieldbus interface 2, transmission rate100 Mbit/s
Ethernet interface, connection type2x socket
Ethernet interface, protocolEasyIP Modbus® TCP OPC UA TCP/IP
Ethernet interface, functionDiagnostics Switch
Ethernet interface, connection systemRJ45
Ethernet interface, connection pattern00995789
Ethernet interface, number of pins/wires8
Ethernet interface, transmission rate10 Mbit/s 100 Mbit/s
Max. address volume, inputs64 Byte
Fieldbus interface, max. address volume for inputs512 Byte
Max. address volume, outputs64 Byte
Fieldbus interface, max. address volume for outputs512 Byte
System parametersDiagnostic memory Fail-safe response System start
Module parametersChannel alarms for undervoltage Process value representation of analogue modules
Configuration supportGSDML file
Additional functionsCoDeSys V3 with SoftMotion
CPU dataDual Core 766 MHz
storage mediumMicro SD <= 32 GB USB memory stick <= 32 GB
Power supply, functionElectronics and sensors
Power supply, connection typeTerminal strip
Power supply, note on connection type> 4 A and UL 2x terminal strip for power supply
power supply, connection systemSpring-loaded terminal
Power supply, connection pattern00995847
Power supply, number of pins/wires4
Nominal DC operating voltage, electronics/sensors24 V
Permissible voltage fluctuations for electronics/sensors± 25%
Power supply, conductor diameter0.2 mm² ... 1.5 mm²
Power supply, note on conductor diameter0.2 - 2.5 mm² for flexible conductors without wire ferrule
Max. power supply8 A
Intrinsic current consumption at nominal operating voltage for electronics/sensorsTypically 150 mA
Power failure bridging20 ms
Reverse polarity protection24 V sensor supply against 0 V sensor supply
USB-interfaceUSB 2.0
Programming softwareCODESYS provided by Festo
Program memory100 MB user program
Processing timeApprox. 200 µs/1 k instruction
Function modulesAnd others Read CPX-E module diagnostics CPX-E diagnostic status Copy CPX-E diagnostic trace
Buffering time real-time clock3 Weeks
FlagCODESYS variable concept