Electrical controlFieldbus Integrated controller
Ambient temperature-5 °C ... 50 °C
Storage temperature-20 °C ... 70 °C
Degree of protectionIP65 IP67
LABS (PWIS) conformityVDMA24364-B2-L
CE mark (see declaration of conformity)To EU EMC Directive To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
KC markKC-EMV
ApprovalRCM trademark c UL us - Recognized (OL)
Explosion protectionZone 2 (ATEX) Zone 2 (RU) Zone 2 (UKEX)
ATEX category gasII 3G
Explosion protection certification outside the EUEPL Gc (GB) EPL Gc (RU)
Explosion ignition protection type for gasEx ec IIC T4 Gc X
Explosion ambient temperature-5°C <= Ta <= +50°C
LED displayBus status Channel status Module status System status
DiagnosisDiagnostic memory Channel-oriented and module-oriented diagnostics Undervoltage of modules
Max. address volume, inputs64 Byte
Max. address volume, outputs64 Byte
ParameterisationDiagnostic behaviour Fail-safe response Forcing of channels Signal setup
Internal cycle time< 1 ms
Operational voltage range DC18 V ... 30 V
Nominal operating voltage DC24 V
Max. power supply16 A