Nominal voltage for logic power supply DC24 V
Nominal operating voltage DC24 V
Nominal current logic power supply0.15 A
Permissible range for logic voltage± 20 %
Current consumption of logic power supply without clamping brake0.2 A
Short circuit current ratingYes, exception: contact C1/C2
Current rating at 40° C0.2 A
Fuse protection (short circuit)no
Digital output designPotential-free signal contact 3 safe, 2-channel semiconductor outputs
Number of digital logic inputs10
Digital outputs, switching logicSemiconductor outputs: parameterisable PNP (positive switching) 2-channel equivalent/antivalent
Dimensions (W x L x H)112.2 x 99.1 x 28.7 mm
LED display, product-specificError (red) Normal operation (green) Safe state (yellow)
Safety functionSafe brake control (SBC) Safe Speed Range (SSR) Safe Speed Monitor (SSM) Safe torque off (STO) Safely limited speed (SLS) Safe Operating Stop (SOS) Safe Stop 1 (SS1) Safe Stop 2 (SS2)
Probability of Failure per Hour (PFH)9.5E-9
Proof test interval20 y
Hardware fault tolerance1
SFF Safe Failure Fraction99.5 %
Certified for safety function to ISO 13849 and IEC 61508 (SIL)Product can be used in SRP/CS up to SIL 3 (high demand)
Safety Integrity Level (SIL)Safe stop 2 (SS2)/SIL 3 Safe stop 1 (SS1)/SIL 3 Safe brake control (SBC)/SIL 3 Safely limited speed (SLS)/SIL 3 Safe operating stop (SOS)/SIL 3 Safe speed monitor (SSM)/SIL 3 Safe Speed Range (SSR)/SIL 3 Safe torque off (STO)/SIL 3
Performance Level (PL)Safe brake control (SBC)/category 4, Performance Level e Safely limited speed (SLS)/category 3, performance level e Safe operating stop (SOS)/category 3, performance level e Safe stop 1 (SS1)/category 3, Performance Level e Safe stop 2 (SS2)/category 3, P
Diagnostic coverage97.5 %
Certified for safety functions to ISO 13849 (PL)Product can be used in SRP/CS up to category 4, PL e
ApprovalGerman Technical Control Board (TÜV)
CE mark (see declaration of conformity)To EU EMC Directive To EC Machinery Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK regulations for machines To UK RoHS instructions
Certificate issuing authorityTÜV Rheinland 01/205/5165.03/24
LABS (PWIS) conformityVDMA24364 zone III
Storage temperature-25 °C ... 55 °C
Relative air humidity5 - 90% Non-condensing
Degree of protectionIP20 In assembled state
Ambient temperature0 °C ... 40 °C
Product weight220 g
Type of mountingPlug-in module for CMMP-AS...-M3
Note on materialsRoHS-compliant
Mounting positionoptional
Wire endsWire ferrule
Connection cross section0.25 mm² ... 0.5 mm²
Electrical connectionScrew terminal Straight plug
DisplayGreen/yellow/red LED
Operator controlsDIP switch
Specification logic inputIEC 61131-2, type 3
Features of logic input4 safe, 2-channel inputs Equivalent/antivalent switching Test pulses configurable Function configurable 6 safe, 1-channel inputs Test pulses configurable
Working range of logic input13 V ... 28.8 V
Max. nominal input current0.015 A
Debounce time for inputs0.3 ms
Current rating per output50 mA
Max. current digital logic outputs50 mA
Fuse capacity of outputsShort-circuit and cross-circuit monitoring
Min. cycle time2 ms
ParameterisationVia SafetyTool