Valve function3-way proportional-pressure regulator, closed
Flow directionNon-reversible
Type of pilotingDirect
Type of resetMechanical spring
Type of actuationElectric
Mounting positionoptional
Grid dimension18 mm
Sealing principleSoft
Total leakage1 l/h
Symbol00995607
Ambient temperature0 °C ... 50 °C
Media temperature5 °C ... 50 °C
Storage temperature-20 °C ... 70 °C
Relative air humidity5 - 85 %
Dimensions (W x L x H)18 x 67 x 66 mm
Pneumatic connection, port 1Flange
Pneumatic connection, port 2Flange
Pneumatic connection, port 3Flange
Material sealsEPDM HNBR NBR
Type of mountingWith through-hole With accessories
Inlet pressure 10 psi ... 94.25 psi
Burst pressure18 bar
Output pressure 20 psi ... 87 psi
Standard nominal flow rate (standardised to DIN 1343)≥20 l/min
Standard nominal flow rate 2-3≥20 l/min
Linearity0.25 %FS
Reproducibility0.2 %FS
Hysteresis0.25 %FS
Temperature cooefficient0.05 %/K
Total accuracy0.5% FS
Product weight70 g
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4] Inert gas
Note on operating and pilot mediumLubricated operation not possible
Nominal altitude of use< 3000 m NHN
Instructions on useThe device has been developed, designed and built exclusively for industrial and commercial use. The device has not been authorised for private use.
Degree of protectionIP65
ApprovalRCM trademark
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Note on materialsRoHS-compliant
LABS (PWIS) conformityVDMA24364 zone III
Corrosion resistance class CRC2 - Moderate corrosion stress
Operational voltage range DC18 V ... 30 V
Nominal operating voltage DC24 V
Max. current consumption0.083 A
Residual ripple10 %
Setpoint value inputIO-Link
Max. electrical power consumption1.5 W
Reverse polarity protectionFor all electrical connections
Short circuit current ratingFor all electrical connections
Safety instructionsError status VEAB: If the electrical power supply fails, the output pressure will be unregulated and may rise or fall – pressure regulator is blocked. The behaviour in the event of loss of IO-Link® communication can be parameterised. Factory setting: Pres
Display typeLED
Electrical connectionM8x1 Plugs To EN 60947-5-2
Max. cable length20 m
Material housingPA-reinforced
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
IO-Link, Number of ports1
IO-Link, Protocol versionDevice V 1.1
IO-Link, Device ID0x03A2
IO-Link, communication modeCOM3 (230.4 kBaud)
IO-Link, port typeClass A
IO-Link, connection technologyDevice 3-pin
IO-Link, Port classDevice A
IO-Link, Min. cycle time0.5 ms
IO-Link, Process data length OUT2 bytes
IO-Link, Process data length IN2 bytes