Valve function2x3/2-way, monostable, closed
Type of actuationElectric
Valve size14 mm
Standard nominal flow rate (standardised to DIN 1343)440 l/min
pneumatic working portFlange
Operating voltage24V DC
Operating pressure-0.9 bar ... 10 bar
DesignPiston gate valve
Type of resetMechanical spring
Approvalc UL us - Recognized (OL)
Degree of protectionIP40
Exhaust-air functionWith flow control option
Sealing principleSoft
Mounting positionoptional
Manual overrideDetenting Non-detenting
Type of pilotingPilot actuated
Pilot air supplyExternal
Flow directionReversible
Symbol00992945
lapOverlap
Signal status displayLED
Pilot pressure2 bar ... 8 bar
Max. switching frequency3 Hz
Switching time off21 ms
Switching time on13 ms
Duty cycle100%
Max. positive test pulse with 0 signal1600 µs
Max. negative test pulse with 1 signal3000 µs
Characteristic coil data22 V DC: 1.0 W
Permissible voltage fluctuations+/- 10 %
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364 zone III
Suitability for the production of Li-ion batteriesSuitable for battery production with reduced Cu/Zn/Ni values (F1a)
Cleanroom suitability, measured according to ISO 14644-14Class 6 according to ISO 14644-1
Media temperature-5 °C ... 60 °C
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Product weight100 g
Electrical connectionVia sub-base
Type of mountingOn manifold rail
Note on materialsRoHS-compliant
Material sealsHNBR NBR
Material housingWrought aluminium alloy