Valve function2x3/2-way, open, monostable
Type of actuationElectric
Construction width52 mm
Standard nominal flow rate (standardised to DIN 1343)2400 l/min
pneumatic working portSub-base size 2 to ISO 5599-2 G1/2
Operating voltage24V DC
Operating pressure3 bar ... 10 bar
DesignPiston gate valve
Approvalc UL us - Recognized (OL)
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive
Degree of protectionIP65 NEMA 4
Grid dimension59 mm
Exhaust-air functionWith flow control option Via throttle plate Via individual sub-base
Sealing principleSoft
Mounting positionoptional
Conforms to standardISO 5599-2
Manual overrideCovered
Type of pilotingPilot actuated
Pilot air supplyExternal
Flow directionNon-reversible
Symbol00995201
Signal status displayLED
Pilot pressure3 bar ... 10 bar
Flow rate of valve3000 l/min
Flow rate of valve on individual sub-base2600 l/min
Flow rate of pneumatically interlinked valve2400 l/min
Switching time off35 ms
Switching time on20 ms
Duty cycle100%
Max. positive test pulse with 0 signal1000 µs
Max. negative test pulse with 1 signal3500 µs
Nominal pick-up current per solenoid coil165 mA up to 30 ms
Nominal current with current reduction35 mA after 30 ms
Characteristic coil data24 V DC: 4.6 W
Immunity to surge2.5 kV
Pollution degree3
Permissible voltage fluctuations+/- 10 %
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature-5 °C ... 50 °C
Relative air humidity0 - 90%
Product weight740 g
Electrical connectionPlug-in To ISO 5599-2
Type of mountingOn sub-base
Pilot air port 12/14Sub-base size 2 to ISO 5599-2
Pilot exhaust port 82/84Ducted Not ducted as per standard Either:
Pneumatic connection, port 1Sub-base size 2 to ISO 5599-2
Pneumatic connection, port 2Sub-base size 2 to ISO 5599-2
Pneumatic connection, port 3Sub-base size 2 to ISO 5599-2
Pneumatic connection, port 4Sub-base size 2 to ISO 5599-2
Pneumatic connection, port 5Sub-base size 2 to ISO 5599-2
Note on materialsRoHS-compliant
Material sealsFPM HNBR NBR
Material housingDie-cast aluminium PA
Material screwsGalvanised steel