Valve function3/2-way, closed, monostable
Type of actuationElectric
Construction width10 mm
Standard nominal flow rate (standardised to DIN 1343)10 l/min
pneumatic working portSub-base
Operating voltage12V DC
Operating pressure0 psi ... 116 psi
DesignPoppet valve with spring return
Type of resetMechanical spring
Degree of protectionIP40
Approvalc UL us - Recognized (OL)
Certificate issuing authorityUL MH19482
Nominal size0.65 mm
Grid dimension10 mm
Exhaust-air functionWith flow control option
Sealing principleSoft
Mounting positionoptional
Manual overrideNon-detenting
Type of pilotingDirect
Flow directionNon-reversible
Symbol00991308
Valve position codeLabel
lapUnderlap
Note on forced dynamizationSwitching frequency min. 1/week
Max. switching frequency20 Hz
Switching time off4 ms
Switching time on4 ms
Duty cycle100%
Electrical power consumption1 W
Characteristic coil data12 V DC: 1.0 W
Permissible voltage fluctuations+/- 10 %
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L
Storage temperature-20 °C ... 60 °C
Media temperature-5 °C ... 40 °C
Ambient temperature-5 °C ... 40 °C
Product weight10 g
Electrical connectionPlugs
Type of mountingOn sub-base With through-hole
Pneumatic connection, port 1Sub-base
Pneumatic connection, port 2Sub-base
Pneumatic connection, port 3Sub-base
Note on materialsRoHS-compliant
Material sealsFPM HNBR NBR
Material housingPPS reinforced