Max. positive test pulse with 0 signal2000 µs
Max. negative test pulse with 1 signal1200 µs
Width40 mm
Length155 mm
Grid dimension41 mm
Valve size40 mm
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Type of actuationElectric
Sealing principleSoft
Mounting positionoptional
Manual overrideDetenting Self-resetting via electrical control signal
DesignPiston gate valve
Type of resetMechanical spring
Type of pilotingPilot actuated
Pilot air supplyInternal
Flow directionNon-reversible
Symbol00997589
Valve functionPressurisation Exhaust
Switching element functionN/C contact
lapUnderlap
Additional functionsHolding current reduction
Note on forced dynamizationSwitching frequency min. 1/month
Signal status displayYellow LED, valve control Green LED, pressure switch, exhausted status
Switching position sensingVia pressure switch, exhausted status
Operating pressure3 bar ... 10 bar
Pilot pressure3 bar ... 8 bar
Switchover pressureNot adjustable Switching point between 50 - 75% of operating pressure
Suitability for vacuumno
Standard nominal flow rate ventilation3000 l/min
Note on standard nominal flow rate, pressurisationMPA: 1200 l/min VTSA: 3000 l/min
Standard nominal flow rate for exhaust3300 l/min
Note on standard nominal flow rate, exhaust airMPA: 1600 l/min VTSA: 3300 l/min
Duty cycle100%
Nominal pick-up current per solenoid coil60 mA to 35 ms
Nominal operating voltage DC24 V
Nominal current with current reduction11 mA after 35 ms
Characteristic coil data24 V DC: 1.6 W
Permissible voltage fluctuations+/- 10 %
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation not possible
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364 zone III
Storage temperature-20 °C ... 60 °C
Media temperature-5 °C ... 50 °C
Relative air humidityMax. 90% at 40°C
Degree of protectionIP65
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Mean time to failure (MTTF), subcomponent452 years, pressure switch
Product weight466 g
Switch-off point min.0.05 bar
Switch-on point0.2 bar
Switch-on point max.0.3 bar
Electrical controlMulti-pin plug
Electrical connectionPlug-in
Sensor connectionPlug 3-pin M12x1
Type of mountingOn sub-base
Pneumatic connection, port 3G1/2
Note on materialsRoHS-compliant
Material sealsHNBR NBR
Material housingWrought aluminium alloy
Material screwsGalvanised steel