Type of actuationElectric
Mounting positionoptional
Conforms to standardISO 20401
Impact energy valueIK06
Signal status displayLED
Duty cycle100%
Insulation material classH
Insulation material class of enamelled wireH
Nominal pick-up current per solenoid coil138 mA up to 70 ms
Nominal current with current reduction50 mA after 70 ms
Characteristic coil data24VDC:NS1,2:HS3.3
Permissible voltage fluctuations+/- 10 %
Approvalc UL us - Recognized (OL)
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC To UK RoHS instructions
Certificate issuing authorityUL MH18122
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature-20 °C ... 60 °C
Degree of protectionIP65
Product weight49.5 g
Max. cable length30 m
Electrical connection 1, connection typePlugs
Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores2
Electrical connection 1, connection pattern00995862
Electrical connection 1, type of mountingScrew-type lock
Type of mountingVia knurled nut
Note on materialsRoHS-compliant
Material housingPA Steel
Material solenoid coilCopper Steel Thermoplastic
Material windingCopper