Type of actuationElectric
Mounting positionoptional
Switching position indicatorno
Duty cycle100%
Required current consumption0.016 A
Insulation material classH
Max. input power Pi1.2 W
Max. input voltage Ui32 V
Max. input current Ii0.2 A
Characteristic coil data14 - 32 V DC: 0.22 - 1.1 W
Effective internal capacitance CiNegligibly low
Effective internal inductivity LiNegligibly low
Permissible voltage fluctuations-15%/+10%
CE mark (see declaration of conformity)To EU EMC Directive To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK instructions for EMC To UK EX instructions To UK RoHS instructions
Explosion protection certification outside the EUEPL Db (GB) EPL Db (IEC-EX) EPL Gb (GB) EPL Gb (IECEx)
Explosion protectionZone 1 (ATEX) Zone 1 (IEC-EX) Zone 1 (UKEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 21 (IEC-EX) Zone 21 (UKEX) Zone 22 (ATEX)
Certificate issuing authorityBVS 15 ATEX E 030 X IECEx BVS 15.0020 X German Technical Control Board (TÜV) 21 UKEX 7016 X
ATEX category gasII 2G
ATEX category dustII 2D
Explosion ignition protection type for gasEx ia IIC T5/T6 Gb
Explosion ignition protection type for dustEx ia IIIC T95°C/T80°C IP65 Db
Explosion ambient temperatureT5/T95°C: -30°C <= Ta <= +65°C T6/T80°C: -30°C <= Ta <= +50°C
LABS (PWIS) conformityVDMA24364 zone III
Degree of protectionIP65
Product weight330 g
Electrical connectionTerminal box, cable entry thread M20x1.5
Note on materialsRoHS-compliant