Valve terminal interfaceType 44, VTSA
DiagnosisWire break per solenoid coil Short circuit of valves Undervoltage of valves
Max. number of valve positions12 with bistable valves 24 with monostable valves
LED display1 Group diagnostics 3 load supply Channel status on valves
ParameterisationFail-safe per channel Forcing per channel Idle mode per channel Module monitoring
Fuse protection (short circuit)Internal electronic fuse protection per valve output
Operational voltage range DC21.6 V ... 26.4 V
Intern power consumption nominal operating voltageTyp. 11 mA (power supply for electronics) Typ. 45 mA (load voltage supply for valve)
Max. power supply per channel0.2 A
Max. total current per module6 A
Nominal operating voltage DC24 V
Isolation channel - internal busyes
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Degree of protectionIP65 NEMA 4
Ambient temperature-5 °C ... 50 °C
Product weight580 g
Electrical controlFieldbus
Electrical connection3x M12x1 A-coded 5-pin Plugs Via CPX
Note on materialsRoHS-compliant
Material coverPA