Nominal size, Laval nozzle2 mm
Silencer designOpen
Reverse polarity protectionFor all electrical connections
Mounting positionoptional
Ejector characteristicHigh vacuum Standard
Manual overrideDetenting Non-detenting Covered
DesignNon-modular
Short circuit current ratingyes
Measured variableRelative pressure
Measuring principlePiezoresistive
Switching functionThreshold value comparator
Integrated functionElectric ejector pulse valve Flow control Electric on-off valve Air saving function, electrical Check valve Open silencer Vacuum switch
Symbol00995768
Valve function5/3-way, pressurised
Switching element functionN/O contact
Setting range hysteresis-0.9 bar ... 0 bar
Setting range threshold value-0.999 bar ... 0 bar
Operating pressure4 bar ... 8 bar
Nominal operating pressure6 bar
Operational voltage range DC21.6 V ... 26.4 V
Inductive protective circuitAdapted to MZ, MY, ME coils
No-load supply current50 mA ... 150 mA
Max. output current50 mA
Duty cycle100%
Voltage drop≤1.5 V
Characteristic coil data24 V DC: 1.3 W
Overload protectionAvailable
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation not possible
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364 zone III
Media temperature0 °C ... 50 °C
Sound pressure level78 dB(A)
Degree of protectionIP65
Product weight1120 g
Pressure measuring range-1 bar ... 0 bar
Accuracy in ± % FS3 %FS
Type of mountingOn sub-base
Pneumatic connection, port 1Sub-base size 26 mm to ISO 15407-2
Pneumatic connection, port 3Sub-base size 26 mm to ISO 15407-2
Note on materialsRoHS-compliant
Material sealsNBR
Material housingWrought aluminium alloy
Material screwsSteel Galvanised
Material connector housingDie-cast zinc Nickel-plated
Material electrical contactBrass Bronze
Material screenPA
Material keypadTPE-U