Construction width18 mm
Based on standardISO 15407-2
Mounting positionoptional
Pilot air supplyExternal
Operating pressure-0.9 bar ... 10 bar
Operational voltage range DC24 V
Immunity to surge4 kV
Current rating at 40° C2 A
Pollution degree3
CE mark (see declaration of conformity)To EU Explosion Protection Directive (ATEX) To EU Low Voltage Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions To UK regulations for electrical equipment
Explosion protection certification outside the EUEPL Gc (GB)
Explosion protectionZone 2 (ATEX) Zone 2 (UKEX)
ATEX category gasII 3G
Explosion ignition protection type for gasEx ec IIC T3 Gc X
explosion group assemblyIIC
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Corrosion resistance class CRC0 - No corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Max. surface temperature assemblyT3
Degree of protectionIP65 NEMA 4 In assembled state
Product weight192 g
Type of mountingWith through-hole To ISO 15407-2
Note on materialsRoHS-compliant
Material sub-baseDie-cast aluminium