Nominal size, Laval nozzle0.7 mm
Grid dimension15 mm
Silencer designClosed
Mounting positionoptional
Ejector characteristicHigh vacuum
Grade of filtration≤40 µm
Manual overrideNon-detenting
Integrated functionElectric on-off valve Filter Vacuum switch
Measured variableRelative pressure
Measuring principlePiezoresistive
Switching element functionN/O contact
Switching functionThreshold value comparator
Symbol00991304
Valve functionClosed
Reverse polarity protectionFor all electrical connections
Display typeLED
Hysteresis setting range-0.05 MPa ... -0.005 MPa
Setting range hysteresis-7.25 psi ... -0.725 psi
Setting optionsPotentiometer
Switching status indicationOptical
Setting range threshold value-13.05 psi ... 0 psi
Operating pressure21.75 psi ... 116 psi
Max. vacuum85 %
Nominal operating pressure87 psi
Air supply time at nominal operating pressure2.2 s
Operational voltage range DC21.6 V ... 26.4 V
Duty cycle100%
Switching outputNPN
ApprovalRCM trademark c UL us - Recognized (OL)
CE mark (see declaration of conformity)To EU EMC Directive
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation not possible
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Media temperature0 °C ... 60 °C
Degree of protectionIP65
Ambient temperature0 °C ... 50 °C
Product weight145 g
Pressure measuring range0 psi ... 14.5 psi
Electrical connectionM8x1 Plugs
Type of mountingWith through-hole Via female thread
Pneumatic connection, port 1M5
Pneumatic connection, port 3Integrated silencer
Vacuum connectionG1/8
Note on materialsRoHS-compliant
Material sealsNBR
Material receiver nozzleBrass, nickel-plated
Material filterPA
Material filter housingPC
Material housingWrought aluminium alloy
Material silencerPE POM
Material pistonPOM
Material transmitter nozzleNickel-plated brass