Valve size27 mm
Valve terminal structureFixed grid
Grid dimension28 mm
Max. number of valve positions8
Exhaust-air functionWithout flow control option
Pilot air supplyExternal Internal
Electrical I/O systemyes
Degree of protectionIP65
LABS (PWIS) conformityVDMA24364 zone III
Note on materialsRoHS-compliant
Material sealsNBR TPE-U(PU)
Fire test materialUL94 HB
Suitable for use with foodSee supplementary material information
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4] Inert gas
Pilot mediumCompressed air to ISO 8573-1:2010 [7:4:4] Inert gases
Note on operating and pilot mediumLubricated operation not possible Condensation in the valve not allowed
Operating pressure43.5 psi ... 116 psi
Pilot pressure43.5 psi ... 116 psi
Note on operating pressure0 - 8 bar with external pilot air Vacuum operation at connection 3 only
Valve functionCan be allocated using the Motion App
Motion AppsLeakage diagnostics Flow control ECO drive Positioning Proportional pressure regulation Proportional directional control valve Soft Stop Presetting of travel time Directional control valve functions Supply and exhaust air flow control Model-based proporti
Type of actuationElectric
Sealing principleSoft
DesignPiston seat
Type of pilotingPilot actuated
Nominal size4.2 mm
Standard flow rate 0.8->0 MPa (8->0 bar, 116->0 psi)1000 l/min
Standard nominal flow rate, air flow 0.6->0,5 MPa (6->5 bar, 87->72.5 psi)450 l/min
Standard nominal flow rate, exhaust 0.6->0.5 MPa (6->5 bar, 87->72.5 psi)480 l/min
Flow directionNon-reversible
Suitability for vacuumyes
Nominal operating voltage DC24 V
Permissible voltage fluctuations+/- 25%
Protection against direct and indirect contactPELV
Approvalc UL us listed (OL)
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Certificate issuing authorityUL E322346
Corrosion resistance class CRC2 - Moderate corrosion stress
Storage temperature-20 °C ... 40 °C
Media temperature5 °C ... 50 °C
Ambient temperature5 °C ... 50 °C
Relative air humidity0 - 90%
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Note on shock resistanceOnly static installation permitted when mounting with a H-rail.
Pneumatic connection, port 2G1/8
Pneumatic connection, port 4G1/8
Pilot air port 14M5
Pneumatic connection, port 1G3/8
Pneumatic connection, port 3G3/8
Pilot exhaust port 84M7
Breather connectionM7