Symbol00995687
ApprovalRCM trademark c UL us listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Certificate issuing authorityUL E322346
Note on materialsRoHS-compliant
Measured variableVoltage
analog input0 - 10 V
Ambient temperature0 °C ... 50 °C
Typical sampling interval1 ms
Accuracy in ± % FS0.5 %FS
Repetition accuracy in ± %FS0.2 %FS
Switching output2 x PNP or 2 x NPN, switchable
Switching functionFreely programmable
Switching element functionN/C or N/O contact, switchable
Max. output current100 mA
Short circuit current ratingyes
ProtocolIO-Link®
IO-Link, Protocol versionDevice V 1.1
IO-Link, ProfileSmart sensor profile
IO-Link, Function classesBinary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel
IO-Link, communication modeCOM2 (38.4 kBaud)
IO-Link, SIO-Mode supportYes
IO-Link, Port classA
IO-Link, Process data length OUT0 bytes
IO-Link, Process data length IN5 bytes
IO-Link, Process data content IN14 bit PDV (measured value InA) 14 bit PDV (measured value InB) 2 bit BDC (measured value monitoring)
IO-Link, Min. cycle time5 ms
IO-Link, Data storage required500 Byte
Operational voltage range DC15 V ... 30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlugs
Electrical connection 1, connector systemConnection pattern L1J
Electrical connection 1, number of connections/cores4
Electrical connection 1, connection pattern00995428
Electrical connection 2, connection type2x socket
Electrical connection 2, connector systemConnection pattern EC
Electrical connection 2, number of connections/cores4
Electrical connection 2, connection pattern00995750
Type of mountingVia wall/surface bracket
Product weight23 g
Material housingPA-reinforced
Display typeIlluminated LCD, multi-colour
Setting optionsIO-Link® Teach-in Via display and keys
Protection against tamperingIO-Link PIN code
Degree of protectionIP40
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L