Symbol00997331
ApprovalRCM trademark c UL us listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Note on materialsRoHS-compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range0 psi
End value for pressure measuring range-14.5 psi
Max. overload pressure5 bar
Overload pressure72.5 psi
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4] Inert gas
Note on operating and pilot mediumLubricated operation possible
Media temperature0 °C ... 50 °C
Ambient temperature0 °C ... 50 °C
Accuracy in ± % FS1.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature coefficient in ± %FS/K0.1 %FS/K
Switching outputPNP/NPN, switchable
Switching functionWindow comparator Threshold value comparator
Switching element functionN/C or N/O contact, switchable
Max. output current80 mA
Short circuit current ratingyes
Operational voltage range DC10.8 V ... 30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlugs
Electrical connection 1, connector systemConnection pattern L1J
Electrical connection 1, number of connections/cores4
Electrical connection 1, connection pattern00995428
Type of mountingFront panel mounting Via wall/surface bracket
Mounting positionoptional
Pneumatic connectionFemale thread M5
Product weight21 g
Material housingPA-reinforced
Material in contact with the mediumAnodised wrought aluminium alloy FPM PA-reinforced
Display typeIlluminated LCD
Displayable unitsMPa bar inHg kPa mmHg psi
Setting optionsTeach-in Via display and keys
Protection against tamperingPIN code
Setting range threshold value0 % ... 100 %
Setting range hysteresis0 % ... 90 %
Degree of protectionIP40
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Suitability for the production of Li-ion batteriesSuitable for battery production with reduced Cu/Zn/Ni values (F1a)
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1