Symbol00995685
ApprovalRCM trademark c UL us listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Certificate issuing authorityUL E322346
Note on materialsRoHS-compliant
Measured variableRelative pressure
Measurement methodPiezoresistive pressure sensor
Start value for pressure measuring range0 psi
End value for pressure measuring range145 psi
Max. overload pressure15 bar
Overload pressure217.5 psi
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4] Inert gas
Note on operating and pilot mediumLubricated operation possible
Media temperature0 °C ... 50 °C
Accuracy in ± % FS1.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Switching output2 x PNP or 2 x NPN, switchable
Switching functionWindow comparator Threshold value comparator Auto difference monitoring
Switching element functionN/C or N/O contact, switchable
Max. output current100 mA
Analogue output0 - 10 V 4 - 20 mA 1 - 5 V
Max. load resistance current output500 Ohm
Min. load resistance voltage output20 kOhm
Short circuit current ratingyes
ProtocolIO-Link®
IO-Link, Protocol versionDevice V 1.1
IO-Link, ProfileSmart sensor profile
IO-Link, Function classesBinary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel
IO-Link, communication modeCOM2 (38.4 kBaud)
IO-Link, SIO-Mode supportYes
IO-Link, Port classA
IO-Link, Process data length OUT0 bytes
IO-Link, Process data length IN2 bytes
IO-Link, Process data content IN14 bit PDV (pressure measurement value) 2 bit BDC (pressure monitoring)
IO-Link, Min. cycle time3 ms
IO-Link, Data storage required500 Byte
Operational voltage range DC15 V ... 30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlugs
Electrical connection 1, connector systemConnection pattern L1J
Electrical connection 1, number of connections/cores4
Electrical connection 1, connection pattern00995428
Type of mountingFront panel mounting Via wall/surface bracket
Mounting positionoptional
Pneumatic connectionFor tubing O.D. 4 mm
Product weight25 g
Material housingPA-reinforced
Material in contact with the mediumFPM NBR PA-reinforced
Display typeIlluminated LCD
Displayable unitsMPa bar inH2O inHg kPa kgf/cm² mbar mmHg psi
Setting optionsIO-Link® Teach-in Via display and keys
Protection against tamperingIO-Link PIN code
Setting range threshold value0 % ... 100 %
Setting range hysteresis0 % ... 90 %
Degree of protectionIP40
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1