DesignBlock design
Conforms to standardEN 60947-5-2
Symbol00995956
ApprovalRCM trademark c UL us listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Certificate issuing authorityUL E232949
Note on materialsRoHS-compliant
Measuring principleOptoelectronic
Detection methodDiffuse sensor
Type of lightRed LED
Max. light spot65 mm at a sensing range of 1000 mm
Operating distance2 mm ... 1000 mm
Ambient temperature-40 °C ... 60 °C
Reference materialStandard white 90%, 100x100 mm
Switching outputPush-pull
Switching element functionSwitchable PNP, light switching NPN, dark switching
Hysteresis200 mm
Max. switching frequency1000 Hz
Max. output current100 mA
Voltage drop0 V ... 1.5 V
Timer functionVia IO-Link®
Short circuit current ratingPulsed
ProtocolIO-Link®
IO-Link, Protocol versionDevice V 1.1
IO-Link, communication modeCOM2 (38.4 kBaud)
IO-Link, SIO-Mode supportYes
IO-Link, Port classA
IO-Link, Process data length OUT2 bit
IO-Link, Process data content OUT1 bit (emitter disable) 1 bit (Hold)
IO-Link, Process data length IN1 bit
IO-Link, Process data content IN1 bit SSC (switching signal)
IO-Link, Min. cycle time2.3 ms
IO-Link, Data storage required2000 Byte
Operational voltage range DC10 V ... 30 V
Residual ripple10 %
No-load supply current25 mA
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlugs
Electrical connection 1, connector systemM8x1, A-coded, to EN 61076-2-104
Electrical connection 1, number of connections/cores3
Electrical connection 1, type of mountingNot rotatable
Electrical connection 1, compatible type of mountingCompatible with latching lock Compatible with rotatable screw-type lock
Electrical connection 1, connection pattern00991155
Material electrical contactGold-plated brass
Type of mountingVia through-hole for M3 screw
Tightening torque0.8 Nm
Mounting positionoptional
Product weight10 g
Material housingPC PMMA
Ready status indicationGreen LED
Switching status indicationYellow LED
Setting optionsIO-Link® Potentiometer Teach-in
Setting range lower limit75 mm
Setting range upper limit1000 mm
Degree of protectionIP65 IP67 IP69K
Insulation voltage500 V
Immunity to surge1 kV
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364 zone III
Pollution degree3