DesignRound
Conforms to standardEN 60947-5-2
Symbol00991712
ApprovalRCM trademark c UL us listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive To EU Low Voltage Directive
UKCA marking (see declaration of conformity)To UK regulations for electrical equipment
Measuring principleInductive
Rated operating distance5 mm
Assured operating distance4.05 mm
Reduction factorsAluminium = 0.4 Stainless steel St 18/8 = 0.7 Copper = 0.3 Brass = 0.4 Steel St 37 = 1.0
Ambient temperature-25 °C ... 85 °C
Repetition accuracy0.15 mm
Switching outputNon-contacting, 2-wire
Switching element functionN/O contact
Hysteresis0.04 mm ... 1.15 mm
Max. switching frequency DC490 Hz
Max. switching frequency AC25 Hz
Max. output current300 mA
Voltage drop≤8 V
Min. load current5 mA
Short circuit current ratingno
Operational voltage range AC20 V ... 265 V
Operational voltage range DC20 V ... 320 V
Mains frequency50 Hz
No-load supply current≤1.5 mA
Reverse polarity protectionFor all electrical connections
Electrical connectionCable
Cable length2.5 m
Material cable sheathTPE-U(PUR)
Material insulating sheathPVC
SizeM18
Type of mountingVia lock nut
Tightening torque30 Nm
Mounting typeFlush
Product weight110 g
Material housingNickel-plated
Switching status indicationYellow LED
Ambient temperature with moving cable-5 °C ... 50 °C
Degree of protectionIP67
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L
Additional information for sensor selectionFor DC and AC voltage
Electrical outputNon-contacting, 2-wire
Selection of sensor designStandard