DesignRound
Conforms to standardEN 60947-5-2
Symbol00991714
ApprovalRCM trademark c UL us listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive To EU Low Voltage Directive
UKCA marking (see declaration of conformity)To UK regulations for electrical equipment
Measuring principleInductive
Rated operating distance4 mm
Assured operating distance3.24 mm
Reduction factorsAluminium = 0.6 Stainless steel St 18/8 = 0.9 Copper = 0.5 Brass = 0.6 Steel St 37 = 1.0
Ambient temperature-25 °C ... 85 °C
Repetition accuracy0.2 mm
Switching outputNon-contacting, 2-wire
Switching element functionN/O contact
Hysteresis0.03 mm ... 0.88 mm
Max. switching frequency DC900 Hz
Max. switching frequency AC25 Hz
Max. output current200 mA
Voltage drop≤8 V
Min. load current5 mA
Short circuit current ratingno
Operational voltage range AC20 V ... 265 V
Operational voltage range DC20 V ... 320 V
Mains frequency50 Hz
No-load supply current≤1.5 mA
Reverse polarity protectionFor all electrical connections
Electrical connectionM12x1 Plugs
SizeM12
Type of mountingVia lock nut
Tightening torque10 Nm
Mounting typeNot flush
Product weight20 g
Material housingNickel-plated
Switching status indicationYellow LED
Degree of protectionIP67
Corrosion resistance class CRC1 - Low corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L
Additional information for sensor selectionFor DC and AC voltage
Electrical outputNon-contacting, 2-wire
Selection of sensor designStandard