Conforms to standardEN 60947-5-2
Symbol00991613
ApprovalRCM trademark c UL us listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)according to UK RoHS instructions (UK-R)
Note on materialsRoHS-compliant
Rated operating distance8 mm
Assured operating distance6.48 mm
Reduction factorsAluminium = 0.35 Stainless steel St 18/8 = 0.7 Copper = 0.3 Brass = 0.4 Steel St 37 = 1.0
Ambient temperature-25 °C ... 70 °C
Repetition accuracy0.4 mm
Switching outputPNP
Switching element functionN/C contact
Hysteresis≤0.88 mm
Max. switching frequency1500 Hz
Max. output current200 mA
Voltage drop≤2 V
Short circuit current ratingPulsed
Operational voltage range DC10 V ... 30 V
Residual ripple+/- 20 %
No-load supply current≤10 mA
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typeCable
Electrical connection 1, connector systemOpen end
Electrical connection 1, number of connections/cores3
Cable length2.5 m
Material cable sheathTPE-U(PUR)
SizeM18
Type of mountingVia lock nut
Tightening torque20 Nm
Mounting typeFlush
Product weight108 g
Material housingPBTP Nickel-plated
Switching status indicationYellow LED
Ambient temperature with moving cable-5 °C ... 70 °C
Degree of protectionIP67
Immunity to surge0.8 kV
LABS (PWIS) conformityVDMA24364-B2-L
Pollution degree3
Additional information for sensor selectionwith increased sensing distance
Electrical outputPNP
Selection of sensor designStandard