Symbol00997525 00997562
ApprovalRCM trademark
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Note on materialsRoHS-compliant
Measured variablePressure Mass flow rate Temperature Volume Volumetric flow rate
Flow directionUnidirectional From left to right
Measuring principleThermal
Measurement methodHeat Loss
Start value for pressure measuring range0 psi
End value for pressure measuring range232 psi
Start value for flow rate measuring range150 l/min
End value for flow rate measuring range15000 l/min
Temperature measurement start value0 °C
Temperature measurement end value100 °C
Operating pressure232 psi
Overload pressure290 psi
Operating mediumArgon Compressed air to ISO 8573-1:2010 [7:4:4] Carbon dioxide Nitrogen
Media temperature0 °C ... 50 °C
Ambient temperature0 °C ... 50 °C
Nominal temperature23 °C
Accuracy of pressure value in ± %FS1.5 %FS
Accuracy of flow rate± (3% o.m.v. + 0.3% FS)
Accuracy temperature in ± °C5 °C
Repetition accuracy of pressure value in ± %FS0.3 %FS
Repetition accuracy offset in ± %FS0.2 %FS
Repetition accuracy span in ± %FS0.8 %FS
Temperature coefficient in ± %FS/K0.05 %FS/K
Temperature coefficient span in ± %FS/KTyp. 0.1%FS/K
Pressure influence span in ± %FS/bar0.5 %FS/b.
Switching output2 x PNP or 2 x NPN, switchable
Switching functionWindow comparator or threshold value comparator, adjustable
Switching element functionN/C or N/O contact, switchable
Max. output current100 mA
Analogue output0 - 10 V 4 - 20 mA 1 - 5 V
Flow characteristic curve start value0 l/min
Flow characteristic curve end value15000 l/min
Temperature characteristic curve start value0 °C
Temperature characteristic curve end value100 °C
Output characteristic curve start value0 V
Output characteristic curve end value20 mA
Output characteristic curve starting value4 mA
Max. load resistance current output500 Ohm
Min. load resistance voltage output20 kOhm
Short circuit current ratingyes
Overload protectionAvailable
ProtocolIO-Link®
IO-Link, revision IDV1.1
IO-Link, device profileFirmware update Function locator Function Product URI Function Quantity detection Identification and diagnostics Smart sensor - SSP 4.1.3
IO-Link, transmission rateCOM3
IO-Link, SIO-Mode supportYes
IO-Link, port typeClass A
IO-Link, process data length output0 bit
IO-Link, process data length input96 bit
IO-Link, Process data content INPressure measured value 16 bit MDC Pressure monitoring 2 bit SSC Flow rate measured value 16-bit MDC Flow rate monitoring 2-bit SSC Temperature measured value 16 bit MDC Temperature monitoring 2-bit SSC Volume / mass pulse 1 bit SSC
IO-Link, Service data INVolume/mass measured value 32 bit Pneumatic energy measurement 32 bit Pneumatic power measurement 32 bit
IO-Link, minimum cycle time1.5 ms
IO-Link, Data storage required1000 Byte
Operational voltage range DC15 V ... 30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlugs
Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores5
Electrical connection 1, type of mountingScrew-type lock
Electrical connection 1, compatible type of mountingCompatible with rotatable screw-type lock
Electrical connection 1, connection pattern00995386
Max. cable length30 m
Type of mountingIn-line installation
Mounting positionoptional
Pneumatic connectionG1 1/2
Product weight600 g
Material housingDie-cast aluminium PA-reinforced
Display typeIlluminated LCD, multi-colour
Displayable unitsMPa bar kPa kg kg/min l l/min m3 m3/h psi scfm scft °C °F
Setting optionsIO-Link® Teach-in Via display and keys
Protection against tamperingIO-Link PIN code
Setting range threshold value0 % ... 100 %
Setting range hysteresis0 % ... 90 %
Degree of protectionIP65
Pressure drop<100 mbar
Protection classIII
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B1/B2-L