Symbol00991853
ApprovalRCM trademark
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
KC markKC-EMV
Note on materialsRoHS-compliant
Measured variableMass flow rate Volumetric flow rate
Flow directionUnidirectional
Measuring principleThermal
Measurement methodHeat Loss
Start value for flow rate sensing range0 l/min
End value for flow rate sensing range1 l/min
Operating pressure-0.9 bar ... 10 bar
Operating mediumCompressed air to ISO 8573-1:2010 [6:4:4] Nitrogen
Media temperature0 °C ... 50 °C
Ambient temperature0 °C ... 50 °C
Nominal temperature23 °C
Repetition accuracy in ± %FS1 %FS
Analogue output1 - 5 V
Rise time3 ms
Min. load resistance voltage output20 kOhm
Short circuit current ratingyes
Overload protectionAvailable
Operational voltage range DC22 V ... 26 V
No-load supply current≤17 mA
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typeCable
Electrical connection 1, connector systemOpen end
Electrical connection 1, number of connections/cores3
Cable length2.5 m
Material cable sheathTPE-U(PUR)
Type of mountingWith through-hole With accessories
Mounting positionoptional
Pneumatic connectionFemale thread M5
Product weight37 g
Material housingPA-reinforced
Degree of protectionIP40
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L
Suitability for the production of Li-ion batteriesSuitable for battery production with reduced Cu/Zn/Ni values (F1a)
Cleanroom suitability, measured according to ISO 14644-14Class 4 according to ISO 14644-1