Symbol00995566
ApprovalRCM trademark c UL us listed (OL)
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Note on materialsRoHS-compliant
Measured variableFlow rate Temperature
Flow directionUnidirectional P1 -> P2
Measurement methodFlow: Vortex Temperature: PT1000
Start value for flow rate measuring range5 l/min
End value for flow rate measuring range100 l/min
Operating pressure0 psi ... 174 psi
Note on operating pressureMax. 1.2 MPa (12 bar / 174 psi) at 40 °C Max. 0.6 MPa (6 bar / 87 psi) at 90 °C
Overload pressure580 psi
Operating mediumLiquid media Water Neutral fluids
Note on operating and pilot mediumMedia with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances in contact with the media must be ensured.
Media temperature0 °C ... 90 °C
Ambient temperature0 °C ... 50 °C
Nominal temperature23 °C
Accuracy of flow rate±2 %FS for flow ≤ 50 %FS ±3% of measured value for flow rate ≥ 50% FS
Accuracy temperature in ± °C2 °C
Repetition accuracy of flow rate< ±0.5% FS for flow rate <= 50 %FS < ±1% of measured value for flow rate >= 50 %FS
Temperature coefficient span in ± %FS/KTyp. ± 0.05%FS/K
Switching output2 x PNP or 2 x NPN, switchable
Switching functionWindow comparator Threshold value comparator Freely programmable
Switching element functionN/C or N/O contact, switchable
Max. output current100 mA
Analogue output0 - 10 V 4 - 20 mA 1 - 5 V
Flow characteristic curve start value0 l/min
Flow characteristic curve end value100 l/min
Max. load resistance current output500 Ohm
Min. load resistance voltage output15 kOhm
Short circuit current ratingyes
Overload protectionAvailable
ProtocolIO-Link®
IO-Link, Protocol versionDevice V 1.1
IO-Link, ProfileSmart sensor profile
IO-Link, Function classesBinary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel
IO-Link, communication modeCOM2 (38.4 kBaud)
IO-Link, SIO-Mode supportYes
IO-Link, Port classA
IO-Link, Process data length OUT0 bytes
IO-Link, Process data length IN3 bytes
IO-Link, Process data content IN1 bit BDC (volume monitoring) 14 bit PDV (measured flow value) 2 bit BDC (flow monitoring)
IO-Link, Service data IN32-bit volume measurement
IO-Link, Min. cycle time5 ms
IO-Link, Data storage required500 Byte
Operational voltage range DC18 V ... 30 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typePlugs
Electrical connection 1, connector systemM12x1, A-coded to EN 61076-2-101
Electrical connection 1, number of connections/cores5
Electrical connection 1, type of mountingNot rotatable
Electrical connection 1, compatible type of mountingCompatible with rotatable screw-type lock
Electrical connection 1, connection pattern00995383
Max. cable length30 m
Mounting positionoptional
Fluid connectionFemale thread G3/4
Product weight530 g
Material housingPA-reinforced
Material in contact with the mediumPA6T/6I reinforced
Displayable unitsUS gal US gal/min cft cft/min l l/h l/min m3 °C °F
Degree of protectionIP65
Corrosion resistance class CRC3 - high corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L