SeriesMS
Size6
Grid dimension62 mm
Safety functionExhaust Prevention of unexpected start-up (pressurisation)
Safety Integrity Level (SIL)Exhaust/SIL 3 Prevention of unexpected start-up (pressurisation)/SIL 3
Performance Level (PL)Exhaust/category 3, performance level d Prevention of unexpected start-up (pressurisation)/category 3, performance level d
Note on forced dynamizationSwitching frequency min. 1/month
DesignPiston seat
lapUnderlap
Type of actuationElectric
Pilot air supplyInternal
Sealing principleSoft
Exhaust-air functionWithout flow control option
Position detection principleMagnetic piston principle
Conforms to standardDIN EN ISO 13849-1 DIN EN ISO 13849-2
Manual overrideNone
Type of resetMechanical spring
Type of pilotingPilot actuated
Symbol00995704
Valve function3/2-way, closed, monostable Soft-start function
Operating pressure3.5 bar ... 10 bar
C value19.3 l/sbar
b value0.21
Standard nominal flow rate (standardised to DIN 1343)4300 l/min
Standard nominal flow rate, exhaust 0.6->0 MPa (6->0 bar, 87->0 psi)9000 l/min
Max. switching frequency0.5 Hz
Switching time off40 ms
Switching time on130 ms
Duty cycle100%
Signal status displayLED Switching outputs
Characteristic coil data24 V DC: 1.8 W
Nominal operating voltage DC24 V
Permissible voltage fluctuations+10%/-15%
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Corrosion resistance class CRC2 - Moderate corrosion stress
Note on materialsRoHS-compliant
LABS (PWIS) conformityVDMA24364-B1/B2-L
Sound pressure level75 dB(A)
Degree of protectionIP65 With plug socket
Media temperature-10 °C ... 50 °C
Ambient temperature-10 °C ... 50 °C
Storage temperature-10 °C ... 50 °C
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
ApprovalRCM trademark
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive To EC Machinery Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK regulations for machines To UK RoHS instructions
Type of mountingEither: In-line installation With accessories
Mounting positionoptional
Product weight2110 g
Pneumatic connection, port 1G1/2
Pneumatic connection, port 2G1/2
Pneumatic connection, port 3G1
Electrical connection4-pin To IEC 61076-2-101
Electrical connection, proximity switch2x cable with plug connector 3-pin M12 Rotatable thread
Cable length0.3 m
Material housingDie-cast aluminium
Material sealsNBR
Material piston rodHigh-alloy stainless steel