Nominal size8 mm
Type of actuationElectric
Sealing principleHard
Mounting positionoptional
DesignPiston gate valve
Type of resetMagnetic spring
Safety instructionsSafety position MPYE: if the power supply cable is blocked, the valve assumes the closed mid-position.
Type of pilotingDirect
Flow directionNon-reversible
Symbol00995308
Valve function5/3 closed
Reverse polarity protectionFor setpoint value
Operating pressure0 bar ... 10 bar
b value0.23
C value6.25 l/sbar
Standard nominal flow rate (standardised to DIN 1343)1400 l/min
Limit frequency80 Hz
Max. hysteresis0.4 %
Operational voltage range DC17 V ... 30 V
Residual ripple5 %
SETPOINT/ACTUAL valuesCurrent type 4-20 mA
ApprovalRCM trademark
KC markKC-EMV
CE mark (see declaration of conformity)To EU EMC Directive In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Operating mediumCompressed air to ISO 8573-1:2010 [6:4:4]
Note on operating and pilot mediumLubricated operation not possible
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L
Media temperature5 °C ... 40 °C
Degree of protectionIP65
Ambient temperature0 °C ... 50 °C
Product weight510 g
Electrical connectionM12x1 Plugs Round design
Type of mountingWith through-hole
Pneumatic connection, port 1G1/4
Pneumatic connection, port 2G1/4
Pneumatic connection, port 3G1/4
Pneumatic connection, port 4G1/4
Pneumatic connection, port 5G1/4
Note on materialsRoHS-compliant
Material coverABS Coated
Material sealsNBR
Material housingAluminium Anodised