Stroke60 mm
Piston diameter22 mm
Max. replacement accuracy0.3 mm
Max. stem backlash Sx0.05 mm
Max. stem backlash Sz0.03 mm
Max. angular gripper jaw backlash ax0.04 deg
Max. angular gripper jaw backlash ay0.07 deg
Max. angular gripper jaw backlash az0.12 deg
Mounting of external fingersThrough-hole
CushioningNo cushioning
Mounting positionoptional
Mode of operationDouble-acting
DesignPiston rod Non-rotating
Position detectionVia proximity switch
Symbol00991216
Protection against torque/guideSquare guide
Minimum product distance due to proximity switches70 mm ... 120 mm
Proximity switch protrusion14 mm ... 22 mm
Operating pressure3 bar ... 8 bar
Advance time480 ms ... 960 ms
Return-stroke time480 ms ... 960 ms
Repetition accuracy0.25 mm
Operating mediumCompressed air to ISO 8573-1:2010 [7:4:4]
Note on operating and pilot mediumLubricated operation possible (in which case lubricated operation will always be required)
Corrosion resistance class CRC2 - Moderate corrosion stress
LABS (PWIS) conformityVDMA24364-B2-L
Degree of protectionIP40
Ambient temperature5 °C ... 60 °C
Max. tightening torque24 Nm for M8 9.9 Nm for M6
Max. force on finger Fz static180 N
Max. torque Mr at finger, static9 Nm
Max. torque at finger Mx static9 Nm
Max. torque at finger My static9 Nm
Theoretical force at 0.6 MPa (6 bar, 87 psi), return stroke180 N
Theoretical force at 0.6 MPa (6 bar, 87 psi), advance stroke225 N
Product weight1000 g
Max. mass per external gripper finger395 g
alternative connectionsM5
Type of mountingWith through-hole for M6 screw and centring sleeve With female thread M8 and centring sleeve
Pneumatic connectionM5
Note on materialsRoHS-compliant
Material coverHigh-alloy steel
Material sealsNBR
Material housingSmooth-anodised wrought aluminium alloy
Material piston rodHigh-alloy steel
Plunger materialHigh-alloy steel
Material gate valveCase-hardened steel