DesignAngular
Based on standardEN 60947-5-6 VDI/VDE 3845
ApprovalRCM trademark c UL us (OL)
CE mark (see declaration of conformity)To EU EMC Directive To EU Explosion Protection Directive (ATEX) In accordance with EU RoHS Directive
UKCA marking (see declaration of conformity)To UK RoHS instructions
Explosion protectionZone 0 (ATEX) Zone 0 (CN) Zone 0 (UKEX) Zone 1 (ATEX) Zone 2 (ATEX) Zone 20 (CN) Zone 20 (UKEX)
ATEX category gasII 1G
Explosion ignition protection type for gasEx ia IIC T6...T1 Ga
Explosion ignition protection type for dustEx ia IIIC T200 135°C Da
Explosion protection certification outside the EUEPL Da (CN) EPL Da (GB) EPL Ga (CN) EPL Ga (GB)
Explosion ambient temperatureSee ATEX certificate See IECEx certificate
Effective internal inductivity Li100 µH
Effective internal capacitance Ci100 nF
Max. intrinsically safe circuit input parameterSee IECEx certificate See ATEX certificate
Certificate issuing authority2020322315003530 CML22UKEX2263X
Note on materialsRoHS-compliant
Safety Integrity Level (SIL)SIL 2
Measuring principleInductive
Ambient temperature-25 °C ... 100 °C
Switching outputNAMUR
Switching element functionN/C contact
Max. switching frequency3000 Hz
Max. output current DC3 mA
Short circuit current ratingyes
Operational voltage range DC8.2 V
Reverse polarity protectionFor all electrical connections
Electrical connection 1, connection typeTerminal strip
Electrical connection 1, cable outletStraight
Electrical connection 1, designRound
Electrical connection 1, connector systemSpring-loaded terminal
Electrical connection 1, number of connections/cores10
Electrical connection 1, connection pattern00995598
Connectable nominal cross section conductor0.2 mm² ... 2.5 mm²
Cable fittingM20x1.5
Type of mountingThreaded
Mounting positionoptional
Product weight170 g
Material housingPBT
Material screwsHigh-alloy stainless steel
Switching status indicationYellow LED
Status indicationLED yellow = valve switching status
Storage temperature-40 °C ... 100 °C
Degree of protectionIP67
Shock resistanceShock test with severity level 2 to FN 942017-5 and EN 60068-2-27
Vibration resistanceTransport application test with severity level 2 to FN 942017-4 and EN 60068-2-6
LABS (PWIS) conformityVDMA24364 zone III
Pollution degree3